{"id":1613,"date":"2026-11-06T11:52:44","date_gmt":"2026-11-06T08:52:44","guid":{"rendered":"https:\/\/setaf2018.com\/?p=1613"},"modified":"2026-11-06T11:52:44","modified_gmt":"2026-11-06T08:52:44","slug":"pressuremeter-test","status":"publish","type":"post","link":"https:\/\/setaf2018.com\/en\/post\/pressuremeter-test\/","title":{"rendered":"The Menard Pressuremeter Test: Modulus, Limit Pressure and Foundation Design"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The pressuremeter test measures the response of soil to a controlled radial expansion inside a borehole. A cylindrical probe is lowered to the test depth, its membrane is inflated in pressure increments, and the volume of fluid injected at each increment is recorded. The result is a stress-strain curve measured in the ground rather than in a laboratory cell.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/setaf2018.com\/wp-content\/uploads\/2026\/09\/pressuremeter-test-blog_featured.webp\" alt=\"Pressuremeter Test: an operator working a pressuremeter control unit beside a borehole on a site investigation\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">That distinction is the reason the test exists. Almost every other route to a deformation modulus passes through a correlation: a blow count converted to a modulus, an index property converted to a stiffness. The pressuremeter measures a stiffness directly, at depth, in material that has not been extracted, transported or trimmed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What it measures is a stiffness in horizontal expansion, which is not the same quantity as the vertical modulus a foundation mobilises. The design methods built around the test account for that difference rather than ignoring it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The pressuremeter is the only routine investigation tool that returns both a stiffness and a strength from the same curve at the same point.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is the Menard Pressuremeter Test?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A borehole expansion test with a three-cell probe.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The probe consists of a central measuring cell and two guard cells above and below it. The guard cells are inflated in parallel with the measuring cell, and their function is to force the expansion of the central section to be cylindrical rather than spherical. Without them the measured volume would include end effects that no analysis can separate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The probe is placed in a pre-drilled borehole, which is the defining feature of the Menard type and the source of its principal weakness. Self-boring and push-in pressuremeters exist precisely to avoid that step, but the Menard device remains the common one because it works in a conventional borehole with conventional drilling equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pressure is applied in equal increments, each held for a fixed interval, commonly sixty seconds, with the injected volume read at thirty and sixty seconds. The test continues until the cavity volume has roughly doubled or the capacity of the equipment is reached.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does the Test Curve Show?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Three distinct phases, and the boundaries between them carry the interpretation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The first phase is recompression. The borehole wall was disturbed and relaxed by drilling, and the initial pressure increments do nothing except push that disturbed annulus back against the intact ground. The curve is steep at first and then flattens as contact is re-established. Nothing about the soil is measured in this phase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The second phase is pseudo-elastic. Once the wall is back in contact, the volume increases nearly linearly with pressure. This is the part of the curve the modulus is taken from, and it is short: in a stiff soil it may cover only three or four increments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The third phase is plastic. The soil around the cavity begins to yield, the volume increases disproportionately with each further increment, and the curve turns towards the horizontal. The pressure at which volume increase becomes unbounded is the limit pressure.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/setaf2018.com\/wp-content\/uploads\/2026\/09\/pressuremeter-test-blog_body-1.webp\" alt=\"Pressuremeter Probe: a slender pressuremeter probe with its membrane sleeve resting beside a borehole casing\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">What Is the Menard Modulus?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The stiffness derived from the slope of the pseudo-elastic phase, interpreted as the expansion of a cylindrical cavity in an elastic medium:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>EM = 2 \u00b7 ( 1 + \u03bd ) \u00b7 Vm \u00b7 ( \u0394p \/ \u0394V )<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where Vm is the mean cavity volume over the linear range, \u0394p \/ \u0394V the slope of that range, and \u03bd the Poisson&#8217;s ratio, conventionally taken as 0.33.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two properties of this quantity are frequently misread. It is a shear modulus scaled into a Young&#8217;s-modulus form by an assumed Poisson&#8217;s ratio, so it is not a drained or undrained modulus in the usual sense, and it is not the vertical modulus that governs settlement under a footing. It is a measured stiffness in horizontal expansion at the strain level the test imposes, which is intermediate rather than small.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because of this, the Menard modulus is not used directly in an elastic settlement expression. It is used within the Menard design rules, which were calibrated against measured foundation settlements with this specific modulus as the input.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is the Limit Pressure?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The pressure at which the soil around the cavity is fully plastic and expansion continues without further load increase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conventionally it is defined as the pressure required to double the initial cavity volume. Because the test rarely reaches that point in practice, the value is obtained by extrapolating the last part of the curve, most commonly on an inverse volume plot.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The quantity used in design is the net limit pressure:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>pL* = pL \u2212 \u03c3h0<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where \u03c3h0 is the total horizontal stress at rest at the test depth. Subtracting it removes the part of the measured pressure that was simply balancing the existing ground stress, leaving the part that represents the resistance of the soil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The limit pressure is a strength quantity. A creep pressure is also identified, at the boundary between the pseudo-elastic and plastic phases, and it is used as a serviceability limit in some applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Are the Results Used in Foundation Design?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Through direct rules that take the pressuremeter values as their input, not through derived soil parameters.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For bearing capacity, the net ultimate bearing pressure of a shallow foundation follows:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>qnet = k \u00b7 pL\\<\/strong>*<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where k is a bearing factor depending on soil type, foundation shape and embedment ratio, and pL* is an equivalent net limit pressure representing the influence zone beneath the foundation rather than a single test value.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For settlement, the Menard rules separate a volumetric component and a deviatoric component, each with its own modulus taken from the relevant depth zone, and apply a rheological factor \u03b1 that depends on soil type and on the ratio of modulus to limit pressure. The factor ranges from about 0.33 in dense sands and gravels to 1.0 in peats and organic soils.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For piles, the shaft friction and the base resistance are both read from the limit pressure profile through published curves that depend on soil type and pile installation method. This is one of the more widely adopted parts of the method, and it is embedded in French practice and in Eurocode 7 national annexes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pattern is consistent. The test outputs feed design expressions calibrated against the test itself, rather than being converted into a friction angle or a cohesion first.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does the EM Over pL Ratio Indicate?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A check on the test as much as a description of the soil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The ratio of Menard modulus to limit pressure falls in characteristic ranges: roughly 5 to 8 in normally consolidated clay, 8 to 15 in overconsolidated clay, and higher again in dense sands. A value substantially below the expected range for the material usually means the borehole wall was disturbed, because disturbance lowers the modulus more than it lowers the limit pressure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This makes the ratio a practical quality filter. A single test with an anomalous ratio in an otherwise consistent profile is more likely a bad borehole than a soft layer, and the profile should be read with that in mind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The ratio is also how the \u03b1 factor is selected in the Menard settlement rules, so it is not a diagnostic quantity only.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Is Borehole Quality the Dominant Variable?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Because the test measures the ground the drilling left behind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A pre-bored pressuremeter is only as good as the hole it sits in. If the wall is smeared, the initial recompression phase extends and the pseudo-elastic range shrinks, leaving too few points to define a slope. If the hole is oversized, the probe expands into a void before touching soil. If the hole has squeezed, the soil is pre-stressed and the modulus reads high.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Practice addresses this through control of the hole rather than through correction of the results. The diameter is matched closely to the probe, the drilling method is chosen for the material, the test is carried out promptly after drilling, and the interval below the casing is limited. None of these are refinements: they are the difference between a usable test and a number with no meaning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is no correction factor for a poor borehole. That is the practical distinction between the pressuremeter and the standard penetration test, where a family of corrections exists for energy, overburden and equipment.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does the Pressuremeter Compare With SPT and CPT?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Each returns a different kind of information, and they are complementary rather than interchangeable.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Test<\/th><th>Directly measured<\/th><th>Stiffness<\/th><th>Continuity<\/th><th>Depends on<\/th><\/tr><\/thead><tbody><tr><td>Pressuremeter<\/td><td>Pressure-volume curve<\/td><td>Measured<\/td><td>Discrete depths<\/td><td>Borehole quality<\/td><\/tr><tr><td>SPT<\/td><td>Blow count<\/td><td>Correlated only<\/td><td>Discrete depths<\/td><td>Energy, equipment, overburden<\/td><\/tr><tr><td>CPT<\/td><td>Tip and sleeve resistance<\/td><td>Correlated only<\/td><td>Continuous profile<\/td><td>Penetrability of the ground<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The pressuremeter is the only one of the three that measures a deformation modulus rather than inferring it. The cost is that it is a discrete test in a borehole, typically at intervals of one to three metres, with no information between test depths. The cone gives a continuous profile but no stiffness measurement, and <a href=\"https:\/\/setaf2018.com\/en\/post\/spt-corrections\/\">SPT blow counts<\/a> give a penetration resistance that reaches a modulus only through <a href=\"https:\/\/setaf2018.com\/en\/post\/spt-n-value-vs-friction-angle\/\">correlation<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In gravels, fills and weathered rock the pressuremeter has an additional advantage: it works where a cone refuses and where an SPT blow count is dominated by particle size rather than by density.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When Is the Pressuremeter the Right Test?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Where stiffness controls the design and correlations are unreliable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It suits deep foundations in variable ground, laterally loaded piles where a horizontal modulus is directly relevant, settlement-controlled foundations on stiff soils, and materials where sampling is not practical: gravels, fills, residual soils and weak rock. It is also a reasonable choice where a design will be carried out under a national annex that adopts the pressuremeter rules explicitly.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It suits less well soft clays, where the pressure range is small relative to the equipment resolution and where undisturbed sampling is viable, and sites where continuous stratigraphic detail matters more than parameter values. It is slower and more expensive per test than either alternative, and it requires an operator whose care with the borehole determines the outcome.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A common arrangement is to use a cone or a borehole log to establish the stratigraphy and the pressuremeter to quantify the layers that govern.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Errors in Pressuremeter Testing and Interpretation<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Error<\/th><th>Consequence<\/th><\/tr><\/thead><tbody><tr><td>Modulus taken across the recompression phase<\/td><td>Stiffness underestimated, sometimes by a large factor<\/td><\/tr><tr><td>Limit pressure read off without extrapolation<\/td><td>Strength underestimated wherever the test stopped early<\/td><\/tr><tr><td>Net limit pressure not reduced by the at-rest horizontal stress<\/td><td>Bearing pressure overestimated, increasingly with depth<\/td><\/tr><tr><td>Menard modulus used directly in an elastic settlement formula<\/td><td>A modulus applied outside the rules it was calibrated for<\/td><\/tr><tr><td>Membrane and volume calibrations not applied<\/td><td>A systematic error carried into every test on the job<\/td><\/tr><tr><td>Oversized or smeared borehole accepted<\/td><td>An unusable curve reported as a soil property<\/td><\/tr><tr><td>Anomalous EM over pL ratio not investigated<\/td><td>A bad test treated as a soft layer in the profile<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Where SETAF2018 Fits<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SETAF2018 carries pressuremeter data as part of the borehole record, alongside the penetration tests and the laboratory results, so a profile that contains pressuremeter measurements is described by all of its data rather than by whichever test the analysis happens to use.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Menard pressuremeter profile is entered against depth in the <a href=\"https:\/\/setaf2018.com\/en\/soil-profile\/\">soil profile<\/a> with the rest of the ground model: layer boundaries, unit weights, groundwater conditions and the in-situ test results. Because the profile is shared, the pressuremeter values sit beside the <a href=\"https:\/\/setaf2018.com\/en\/post\/spt-corrections\/\">corrected SPT blow counts<\/a> and the laboratory-derived parameters for the same depths, which is what makes a consistency check between them possible at all.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Analysis in the software proceeds through the classical routes: Terzaghi, Meyerhof and Vesi\u0107 for <a href=\"https:\/\/setaf2018.com\/en\/bearing-capacity-of-foundations\/\">bearing capacity<\/a>, Boussinesq and Mindlin\u2013Geddes for <a href=\"https:\/\/setaf2018.com\/en\/post\/foundation-settlement-analysis\/\">settlement<\/a>, and the \u03b1, \u03bb and \u03b2 methods for <a href=\"https:\/\/setaf2018.com\/en\/post\/pile-axial-capacity\/\">pile capacity<\/a>. The pressuremeter profile documents the ground rather than driving these calculations, and the derived parameters that do drive them come from the correlations and laboratory data in the same model.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Calculation <a href=\"https:\/\/setaf2018.com\/en\/reports\/\">reports<\/a> print the borehole record together with the expressions and the intermediate values, so the data behind a design decision stays visible, and the <a href=\"https:\/\/setaf2018.com\/en\/post\/geotechnical-report\/\">geotechnical report<\/a> carries the field information into the drawings and the deliverables.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What the software does not perform is direct Menard-rule foundation design from the limit pressure, nor pressuremeter curve reduction from raw field readings.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What does the pressuremeter test measure?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It measures the pressure-volume response of soil to a controlled radial expansion in a borehole. From that single curve it returns a deformation modulus, a creep pressure and a limit pressure, so one test gives both a stiffness and a strength at the same depth.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the Menard modulus?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It is the stiffness calculated from the slope of the pseudo-elastic part of the pressure-volume curve, interpreted as cylindrical cavity expansion in an elastic medium with an assumed Poisson&#8217;s ratio of 0.33. It is a horizontal expansion stiffness at intermediate strain, not a vertical modulus.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the limit pressure in a pressuremeter test?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It is the pressure at which the soil around the cavity is fully plastic and expansion continues without a further pressure increase, conventionally defined as the pressure that doubles the initial cavity volume. In design the net value, after subtracting the at-rest horizontal stress, is the quantity used.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why is the pressuremeter modulus not used in a standard elastic settlement formula?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because it was not calibrated that way. The Menard modulus enters the Menard settlement rules, which separate volumetric and deviatoric components and apply a rheological factor for soil type. Substituting it into a general elastic expression applies it outside the framework it belongs to.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How does the pressuremeter compare with the SPT?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The pressuremeter measures a stiffness directly, while an SPT blow count reaches a modulus only through correlation. The SPT is faster, cheaper and far more widely available; the pressuremeter gives more information per test and works in gravels and fills where penetration testing is unreliable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the EM over pL ratio used for?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It indicates soil type and consolidation state, running from roughly 5 to 8 in normally consolidated clay to considerably higher in dense granular soils. It also serves as a quality check, because a low ratio for the material usually signals borehole disturbance rather than a soft layer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What makes a pressuremeter test unreliable?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Borehole quality, more than any other factor. A smeared, oversized or squeezed hole distorts the early part of the curve, and there is no correction factor that recovers the result. Matching the hole diameter to the probe and testing promptly after drilling matter more than any interpretation refinement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can the pressuremeter be used for pile design?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. Shaft friction and base resistance are read from the limit pressure profile through published curves that depend on soil type and installation method. This is one of the most widely adopted parts of the method and appears in Eurocode 7 national annexes in several countries.<\/p>\n\n\n\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does the pressuremeter test measure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It measures the pressure-volume response of soil to a controlled radial expansion in a borehole. From that single curve it returns a deformation modulus, a creep pressure and a limit pressure, so one test gives both a stiffness and a strength at the same depth.\"}}, {\"@type\": \"Question\", \"name\": \"What is the Menard modulus?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is the stiffness calculated from the slope of the pseudo-elastic part of the pressure-volume curve, interpreted as cylindrical cavity expansion in an elastic medium with an assumed Poisson's ratio of 0.33. It is a horizontal expansion stiffness at intermediate strain, not a vertical modulus.\"}}, {\"@type\": \"Question\", \"name\": \"What is the limit pressure in a pressuremeter test?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is the pressure at which the soil around the cavity is fully plastic and expansion continues without a further pressure increase, conventionally defined as the pressure that doubles the initial cavity volume. In design the net value, after subtracting the at-rest horizontal stress, is the quantity used.\"}}, {\"@type\": \"Question\", \"name\": \"Why is the pressuremeter modulus not used in a standard elastic settlement formula?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Because it was not calibrated that way. The Menard modulus enters the Menard settlement rules, which separate volumetric and deviatoric components and apply a rheological factor for soil type. Substituting it into a general elastic expression applies it outside the framework it belongs to.\"}}, {\"@type\": \"Question\", \"name\": \"How does the pressuremeter compare with the SPT?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The pressuremeter measures a stiffness directly, while an SPT blow count reaches a modulus only through correlation. The SPT is faster, cheaper and far more widely available; the pressuremeter gives more information per test and works in gravels and fills where penetration testing is unreliable.\"}}, {\"@type\": \"Question\", \"name\": \"What is the EM over pL ratio used for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It indicates soil type and consolidation state, running from roughly 5 to 8 in normally consolidated clay to considerably higher in dense granular soils. It also serves as a quality check, because a low ratio for the material usually signals borehole disturbance rather than a soft layer.\"}}, {\"@type\": \"Question\", \"name\": \"What makes a pressuremeter test unreliable?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Borehole quality, more than any other factor. A smeared, oversized or squeezed hole distorts the early part of the curve, and there is no correction factor that recovers the result. Matching the hole diameter to the probe and testing promptly after drilling matter more than any interpretation refinement.\"}}, {\"@type\": \"Question\", \"name\": \"Can the pressuremeter be used for pile design?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Shaft friction and base resistance are read from the limit pressure profile through published curves that depend on soil type and installation method. This is one of the most widely adopted parts of the method and appears in Eurocode 7 national annexes in several countries.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>How the Menard pressuremeter test works, what the Menard modulus and the limit pressure really mean, and how both are used in foundation and pile design.<\/p>\n","protected":false},"author":2,"featured_media":1611,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Menard Pressuremeter Test: Modulus and Limit Pressure","rank_math_description":"How the Menard pressuremeter test works, what the Menard modulus and the limit pressure really mean, and how both are used in foundation and pile design.","rank_math_focus_keyword":"pressuremeter test"},"categories":[53],"tags":[],"class_list":["post-1613","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-in-situ-testing"],"_links":{"self":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/1613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/comments?post=1613"}],"version-history":[{"count":12,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/1613\/revisions"}],"predecessor-version":[{"id":1648,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/1613\/revisions\/1648"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/media\/1611"}],"wp:attachment":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/media?parent=1613"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/categories?post=1613"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/tags?post=1613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}