{"id":1626,"date":"2026-11-06T12:03:51","date_gmt":"2026-11-06T09:03:51","guid":{"rendered":"https:\/\/setaf2018.com\/?p=1626"},"modified":"2026-11-06T12:03:51","modified_gmt":"2026-11-06T09:03:51","slug":"eurocode-7-design-approach-2","status":"publish","type":"post","link":"https:\/\/setaf2018.com\/en\/post\/eurocode-7-design-approach-2\/","title":{"rendered":"Eurocode 7 Design Approach 2 in Practice: Partial Factors for Foundations and Retaining Structures"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Design Approach 2 is one of the three routes Eurocode 7 offers for verifying an ultimate limit state in geotechnical design. It applies partial factors to actions and to resistances, and leaves the soil parameters unfactored, which makes it the approach closest in structure to how a structural engineer verifies a member.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/setaf2018.com\/wp-content\/uploads\/2026\/09\/eurocode-7-design-approach-2-blog_featured.webp\" alt=\"Eurocode 7 Design: two engineers reviewing foundation drawings with an open code volume at a design office desk\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">That similarity is why it was adopted in several national annexes, and it is also why it is misapplied. The partial factors are easy to quote and hard to place correctly, because Design Approach 2 has two variants that differ in where the action factors are applied, and the difference changes the answer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The partial factor values are the easy part of Design Approach 2. Where in the calculation they are applied is the part that decides the result.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does Eurocode 7 Actually Require?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">That a design effect of actions does not exceed a design resistance:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ed \u2264 Rd<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The design effect Ed is derived from the characteristic actions multiplied by partial action factors. The design resistance Rd is derived from the characteristic resistance divided by a partial resistance factor, with the soil parameters themselves either factored or not depending on the approach in use.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Everything else in the code is machinery around that inequality: which limit states have to be checked, how characteristic values are selected, and which of the three Design Approaches supplies the numbers. The inequality never changes, but the route to both sides of it does.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Are the Three Design Approaches?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Three different distributions of the same safety margin.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Approach<\/th><th>Factors on actions<\/th><th>Factors on soil parameters<\/th><th>Factors on resistance<\/th><\/tr><\/thead><tbody><tr><td>DA1, combination 1<\/td><td>Yes (A1)<\/td><td>No (M1)<\/td><td>No (R1)<\/td><\/tr><tr><td>DA1, combination 2<\/td><td>Partly (A2)<\/td><td>Yes (M2)<\/td><td>No (R1)<\/td><\/tr><tr><td>DA2<\/td><td>Yes (A1)<\/td><td>No (M1)<\/td><td>Yes (R2)<\/td><\/tr><tr><td>DA3<\/td><td>Yes (A1 or A2)<\/td><td>Yes (M2)<\/td><td>No (R3)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Design Approach 1 requires two separate verifications and the governing one may be either. Design Approach 3 factors the soil strength, which makes it natural for slope stability and for problems where the failure mechanism itself depends on the strength. Design Approach 2 requires a single calculation with a resistance factor, which is why it maps neatly onto a bearing capacity or a sliding check.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The choice is not the designer&#8217;s. Each national annex specifies which approach applies to which type of structure, and the same building analysed in two countries may be verified by two different routes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Defines Design Approach 2?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A single combination, factored actions, unfactored soil parameters and a factored resistance: the A1 &#8220;+&#8221; M1 &#8220;+&#8221; R2 set.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The soil parameters used in the calculation are the characteristic values, with every material factor in set M1 equal to 1.0. This is the defining feature. The friction angle, the cohesion and the undrained strength enter the bearing capacity expression exactly as the ground investigation established them, and the safety against the ground is supplied afterwards, by dividing the computed resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The practical consequence is that the failure mechanism computed in Design Approach 2 is the characteristic one. The failure surface, the effective foundation area and the earth pressure distribution are those of the unfactored soil, which is not true in Design Approach 3, where factoring the strength changes the mechanism as well as the magnitude.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Which Partial Factors Apply in DA2?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The values below are the recommended ones in EN 1997-1. A national annex may change any of them, and several do.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Quantity<\/th><th>Set<\/th><th>Symbol<\/th><th>Recommended value<\/th><\/tr><\/thead><tbody><tr><td>Permanent action, unfavourable<\/td><td>A1<\/td><td>\u03b3G<\/td><td>1.35<\/td><\/tr><tr><td>Permanent action, favourable<\/td><td>A1<\/td><td>\u03b3G,fav<\/td><td>1.00<\/td><\/tr><tr><td>Variable action, unfavourable<\/td><td>A1<\/td><td>\u03b3Q<\/td><td>1.50<\/td><\/tr><tr><td>Variable action, favourable<\/td><td>A1<\/td><td>\u03b3Q,fav<\/td><td>0<\/td><\/tr><tr><td>All soil parameters<\/td><td>M1<\/td><td>\u03b3\u03c6, \u03b3c, \u03b3cu, \u03b3\u03b3<\/td><td>1.00<\/td><\/tr><tr><td>Bearing resistance, spread foundation<\/td><td>R2<\/td><td>\u03b3R,v<\/td><td>1.40<\/td><\/tr><tr><td>Sliding resistance, spread foundation<\/td><td>R2<\/td><td>\u03b3R,h<\/td><td>1.10<\/td><\/tr><tr><td>Earth resistance, retaining structure<\/td><td>R2<\/td><td>\u03b3R,e<\/td><td>1.40<\/td><\/tr><tr><td>Pile base and shaft resistance<\/td><td>R2<\/td><td>\u03b3b, \u03b3s<\/td><td>1.10<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Two points are worth holding onto. A favourable permanent action takes 1.0 and not 1.35, which matters wherever self-weight stabilises rather than loads: an overturning check, a sliding check, an uplift verification. And the bearing resistance factor of 1.4 is not a global factor of safety of 1.4, because the actions on the other side of the inequality have already been increased.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is the Difference Between DA2 and DA2*?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Where the action factors are applied, and it is the most consequential detail in the approach.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In Design Approach 2 as written, the characteristic actions are factored first, and the geotechnical calculation is then carried out with design values throughout. In the variant written DA2*, the entire geotechnical calculation is performed with characteristic values, and the factors are applied at the very end, to the resulting effect and resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a linear problem the two give the same answer. Geotechnical problems are frequently not linear. A foundation with an eccentric load is the clearest case: the effective foundation area depends on the eccentricity, the eccentricity depends on the ratio of moment to vertical load, and factoring the moment and the vertical load by different amounts changes that ratio. DA2 computes the bearing capacity on a smaller effective area than DA2* does, and the two results diverge as eccentricity grows.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Earth pressure calculations behave the same way, because the pressure distribution and the point of application respond to the factored surcharge differently from the way a single multiplier at the end would suggest.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Neither variant is universally more conservative. Which one applies is set by the national annex, and German practice in particular uses DA2*. A calculation that does not state which variant it used cannot be checked.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/setaf2018.com\/wp-content\/uploads\/2026\/09\/eurocode-7-design-approach-2-blog_body-1.webp\" alt=\"Foundation Construction: a reinforcement cage set in a shuttered pad foundation excavation with an engineer checking the bars\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">How Does DA2 Work for a Spread Foundation?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Through the same <a href=\"https:\/\/setaf2018.com\/en\/bearing-capacity-of-foundations\/\">bearing capacity<\/a> expression used elsewhere, with the factors placed around it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The characteristic bearing resistance is computed from the unfactored soil parameters, using the <a href=\"https:\/\/setaf2018.com\/en\/post\/bearing-capacity-factors\/\">bearing capacity factors<\/a> with their shape, depth and inclination corrections, over the effective foundation area. That resistance is divided by 1.4. On the other side, the permanent and variable actions are multiplied by 1.35 and 1.5, and the comparison is made.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sliding is verified separately with its own resistance factor of 1.1, and the two checks can be governed by different load combinations: the one that maximises vertical load is not the one that maximises the horizontal-to-vertical ratio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Serviceability is a separate verification with all partial factors equal to 1.0. A foundation that satisfies Design Approach 2 comfortably can still fail a settlement limit, and on soft or compressible ground it frequently does. The ultimate limit state check does not say anything about movement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does DA2 Work for Pile Design?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">With an additional layer of factors that has no counterpart in shallow foundation design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pile resistance derived from ground test results is first reduced by a correlation factor, written \u03be3 or \u03be4, which depends on the number of test profiles across the site. Fewer profiles means a larger correlation factor and a smaller design resistance, so the investigation density enters the design value directly. Resistance derived from static load tests uses \u03be1 and \u03be2 in the same role.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Only after the correlation factor is applied does the partial resistance factor enter, at 1.1 on base and shaft in set R2. A model factor may also be specified by the national annex, applied on top.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The chain matters because the resistance factor of 1.1 looks much smaller than the 1.4 used for a spread foundation, and it is not comparable in isolation: the correlation factor has already done part of the work, and <a href=\"https:\/\/setaf2018.com\/en\/post\/pile-axial-capacity\/\">pile capacity<\/a> design values from a sparse investigation are reduced substantially before 1.1 is ever applied.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Is DA2 Rarely Used for Walls and Slopes?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Because a resistance factor requires a resistance that can be separated from the action, and in these problems it cannot.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In an <a href=\"https:\/\/setaf2018.com\/en\/excavation-support-structures\/\">embedded retaining wall<\/a>, the same soil supplies the driving <a href=\"https:\/\/setaf2018.com\/en\/post\/earth-pressure-coefficients\/\">earth pressure<\/a> on one side and the resisting pressure on the other. Factoring the resistance side while leaving the driving side unfactored produces a stress state that has no physical meaning, and the required embedment depth becomes sensitive to an essentially arbitrary split. Several national annexes therefore direct embedded walls to Design Approach 1 or 3 even where DA2 governs shallow foundations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Slope stability is worse. The output of a <a href=\"https:\/\/setaf2018.com\/en\/post\/fellenius-vs-bishop-slope-stability\/\">slope stability<\/a> analysis is a ratio of resisting to driving moment along a surface found by search, and there is no separable resistance to divide. Design Approach 3, which factors the shear strength before the search, produces a critical surface consistent with the factored material. This is why almost every national annex assigns slopes to DA3.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Do Characteristic Values Enter the Calculation?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">They are selected, not measured, and the selection carries more weight than the partial factors do.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eurocode 7 defines the characteristic value as a cautious estimate of the value affecting the occurrence of the limit state. Not the mean, not the minimum, and not a fixed percentile: a cautious estimate of the value that governs, which depends on how much soil the mechanism involves. A large failure surface averages local variation, so the cautious estimate approaches the mean; a small, locally controlled mechanism does not, so the estimate moves towards the lower values.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two engineers working from the same borehole data and the same <a href=\"https:\/\/setaf2018.com\/en\/soil-profile\/\">soil profile<\/a> can select characteristic values that differ by more than the partial factors that follow them. Whether the <a href=\"https:\/\/setaf2018.com\/en\/post\/undrained-shear-strength-correlations\/\">undrained strength<\/a> is taken from a correlation or a test, and which cautious estimate is drawn from a scattered set of results, changes the design value before any factor is applied.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is the part of Eurocode 7 that resists codification, and it is the part a reviewer should examine first.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does DA2 Compare With Global Factor of Safety Design?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The total margin is similar; its distribution is not.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Traditional practice applies a single global factor, commonly 3.0 on ultimate bearing capacity, to unfactored actions and unfactored parameters. Design Approach 2 splits a comparable margin between the action side and the resistance side. For a foundation carrying mostly permanent load, the combined effect of 1.35 on actions and 1.4 on resistance is roughly 1.9, which appears far less conservative than 3.0 until the difference in what each covers is taken into account: the global factor also absorbs settlement concerns and model uncertainty that the limit state format handles in separate verifications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The practical difference is transparency rather than severity. In the partial factor format, the allowance made for action uncertainty and the allowance made for ground uncertainty are visible as separate numbers, and a designer can see which one governs. In the global format they are combined into a single value chosen by precedent.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Direct comparison of the two formats on one project is therefore meaningless unless the serviceability check is included on the Eurocode side.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Errors in Applying Design Approach 2<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Error<\/th><th>Consequence<\/th><\/tr><\/thead><tbody><tr><td>Factoring soil parameters as well as the resistance<\/td><td>Safety counted twice; the M1 set is 1.0 by definition<\/td><\/tr><tr><td>Applying 1.35 to a stabilising permanent action<\/td><td>Overturning and sliding checks made unsafe, not conservative<\/td><\/tr><tr><td>Not stating whether DA2 or DA2* was used<\/td><td>The calculation cannot be reproduced or checked<\/td><\/tr><tr><td>Treating \u03b3R,v = 1.4 as a global factor of safety<\/td><td>The factored actions on the other side are ignored<\/td><\/tr><tr><td>Omitting the pile correlation factor before \u03b3b and \u03b3s<\/td><td>Design resistance overestimated, most on sparse investigations<\/td><\/tr><tr><td>Assuming DA2 covers serviceability<\/td><td>Settlement unverified; the ULS check says nothing about movement<\/td><\/tr><tr><td>Using recommended values instead of the national annex<\/td><td>The wrong factor set for the country the structure is built in<\/td><\/tr><tr><td>Applying DA2 to an embedded wall where the annex requires DA1 or DA3<\/td><td>Embedment depth derived from a split with no physical basis<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Where SETAF2018 Fits<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SETAF2018 verifies foundations and excavation support structures to Eurocode 7 Design Approach 2 directly. The partial factor sets are applied inside the software, on the action side and on the resistance side, so what comes out is a DA2 verification rather than a characteristic resistance left for someone else to factor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The partial factors are user-definable. Where a national annex departs from the recommended values &mdash; and several do &mdash; the annex values are entered and used, which is how the same model is verified to the factor set of whichever country the structure is built in. Where an annex assigns a different approach to a structure type &mdash; embedded walls being the common case &mdash; the factor set is changed to match, so the verification follows the route the annex requires rather than a route fixed by the software.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The resistance side is computed with the methods the approach expects. <a href=\"https:\/\/setaf2018.com\/en\/bearing-capacity-of-foundations\/\">Bearing capacity<\/a> is computed by the Terzaghi, Meyerhof and Vesi\u0107 formulations with shape, depth and inclination corrections over the effective foundation area, from parameters derived in the shared <a href=\"https:\/\/setaf2018.com\/en\/soil-profile\/\">soil profile<\/a>. Settlement follows Boussinesq and Mindlin\u2013Geddes, and <a href=\"https:\/\/setaf2018.com\/en\/post\/pile-axial-capacity\/\">pile capacity<\/a> through the \u03b1, \u03bb and \u03b2 methods with group efficiency by Converse\u2013Labarre and the Terzaghi block. Excavation support is analysed by the dependent pressures method with elasto-plastic Winkler springs, and slope stability by Fellenius and simplified Bishop.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because the <a href=\"https:\/\/setaf2018.com\/en\/reports\/\">reports<\/a> print the full expressions, the input values and the intermediate results rather than a final number alone, both sides of E<sub>d<\/sub> &le; R<sub>d<\/sub> are visible as quantities: which factor was applied where, and what the resistance was before it was divided. That is what makes a Design Approach 2 calculation reproducible by a checker rather than only by its author.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Verification to TBDY 2018 requirements, including the liquefaction assessment in Annex 16B, is carried out inside the software directly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What is Design Approach 2 in Eurocode 7?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It is the verification route that applies partial factors to actions and to resistances while leaving soil parameters unfactored, using the A1 &#8220;+&#8221; M1 &#8220;+&#8221; R2 factor sets. A single calculation is required, unlike Design Approach 1, which needs two combinations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What partial factors does DA2 use?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The recommended values are 1.35 on unfavourable permanent actions, 1.5 on unfavourable variable actions, 1.0 on all soil parameters, 1.4 on bearing resistance, 1.1 on sliding resistance and 1.4 on earth resistance. National annexes may specify different values.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between DA2 and DA2*?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In DA2 the actions are factored before the geotechnical calculation, so the whole calculation runs on design values. In DA2* the calculation runs on characteristic values and the factors are applied at the end. The results differ in non-linear problems such as eccentrically loaded foundations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why are soil parameters not factored in DA2?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because the safety against ground uncertainty is supplied by the resistance factor instead. Set M1 has every material factor equal to 1.0 by definition, so factoring the parameters as well would apply the same margin twice and produce an over-conservative design.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Which Design Approach should be used?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The national annex of the country where the structure is built specifies it, often differently for different structure types. Design Approach 2 is commonly assigned to spread foundations and piles, Design Approach 3 to slopes, and embedded retaining walls vary between annexes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does DA2 apply to slope stability?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Rarely. A slope analysis produces a ratio of resisting to driving moment with no separable resistance to divide, and the critical surface depends on the shear strength. Design Approach 3, which factors the strength before the surface is searched, is assigned to slopes in almost every national annex.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How are pile resistances factored in DA2?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Resistance from ground test results is first divided by a correlation factor that depends on the number of test profiles, then by the partial resistance factor of 1.1 on base and shaft. A model factor may be added by the national annex. The correlation factor often dominates.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does Design Approach 2 cover settlement?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. It is an ultimate limit state verification. Serviceability is a separate check carried out with all partial factors equal to 1.0 against deformation limits. A foundation can satisfy DA2 comfortably and still exceed an allowable settlement on compressible ground.<\/p>\n\n\n\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is Design Approach 2 in Eurocode 7?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is the verification route that applies partial factors to actions and to resistances while leaving soil parameters unfactored, using the A1, M1 and R2 factor sets. A single calculation is required, unlike Design Approach 1, which needs two combinations.\"}}, {\"@type\": \"Question\", \"name\": \"What partial factors does DA2 use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The recommended values are 1.35 on unfavourable permanent actions, 1.5 on unfavourable variable actions, 1.0 on all soil parameters, 1.4 on bearing resistance, 1.1 on sliding resistance and 1.4 on earth resistance. National annexes may specify different values.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between DA2 and DA2*?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In DA2 the actions are factored before the geotechnical calculation, so the whole calculation runs on design values. In DA2* the calculation runs on characteristic values and the factors are applied at the end. The results differ in non-linear problems such as eccentrically loaded foundations.\"}}, {\"@type\": \"Question\", \"name\": \"Why are soil parameters not factored in DA2?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Because the safety against ground uncertainty is supplied by the resistance factor instead. Set M1 has every material factor equal to 1.0 by definition, so factoring the parameters as well would apply the same margin twice and produce an over-conservative design.\"}}, {\"@type\": \"Question\", \"name\": \"Which Design Approach should be used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The national annex of the country where the structure is built specifies it, often differently for different structure types. Design Approach 2 is commonly assigned to spread foundations and piles, Design Approach 3 to slopes, and embedded retaining walls vary between annexes.\"}}, {\"@type\": \"Question\", \"name\": \"Does DA2 apply to slope stability?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Rarely. A slope analysis produces a ratio of resisting to driving moment with no separable resistance to divide, and the critical surface depends on the shear strength. Design Approach 3, which factors the strength before the surface is searched, is assigned to slopes in almost every national annex.\"}}, {\"@type\": \"Question\", \"name\": \"How are pile resistances factored in DA2?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Resistance from ground test results is first divided by a correlation factor that depends on the number of test profiles, then by the partial resistance factor of 1.1 on base and shaft. A model factor may be added by the national annex. The correlation factor often dominates.\"}}, {\"@type\": \"Question\", \"name\": \"Does Design Approach 2 cover settlement?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is an ultimate limit state verification. Serviceability is a separate check carried out with all partial factors equal to 1.0 against deformation limits. A foundation can satisfy DA2 comfortably and still exceed an allowable settlement on compressible ground.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>What Eurocode 7 Design Approach 2 requires, the partial factors it uses, how DA2 differs from DA2 star, and why slopes and walls are handled elsewhere.<\/p>\n","protected":false},"author":2,"featured_media":1624,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Eurocode 7 Design Approach 2: Partial Factors in Practice","rank_math_description":"What Eurocode 7 Design Approach 2 requires, the partial factors it uses, how DA2 differs from DA2 star, and why slopes and walls are handled elsewhere.","rank_math_focus_keyword":"eurocode 7 design approach 2"},"categories":[54],"tags":[],"class_list":["post-1626","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standards"],"_links":{"self":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/1626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/comments?post=1626"}],"version-history":[{"count":22,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/1626\/revisions"}],"predecessor-version":[{"id":1962,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/1626\/revisions\/1962"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/media\/1624"}],"wp:attachment":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/media?parent=1626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/categories?post=1626"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/tags?post=1626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}