{"id":2035,"date":"2026-11-22T22:26:46","date_gmt":"2026-11-22T19:26:46","guid":{"rendered":"https:\/\/setaf2018.com\/post\/coefficient-of-permeability\/"},"modified":"2026-11-22T22:26:46","modified_gmt":"2026-11-22T19:26:46","slug":"coefficient-of-permeability","status":"publish","type":"post","link":"https:\/\/setaf2018.com\/en\/post\/coefficient-of-permeability\/","title":{"rendered":"Coefficient of Permeability: Test Methods, Typical Values and Uses"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The coefficient of permeability, k, is the rate at which water flows through a saturated soil under a unit hydraulic gradient, expressed as a velocity in metres per second. It is the proportionality constant in Darcy&#8217;s law and is called hydraulic conductivity in hydrogeology.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/setaf2018.com\/wp-content\/uploads\/2026\/11\/coefficient-of-permeability-blog_featured.webp\" alt=\"Coefficient of Permeability: a technician running a constant head permeameter test on a sand specimen in a laboratory\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The value depends on the size and continuity of the voids rather than on their total volume. A clean gravel and an intact clay can have comparable porosities, yet water moves through the gravel millions of times faster, because flow is controlled by the narrowest connected pore channels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the engineer, k sets the time scale of consolidation, the inflow into an excavation, the pore pressure response to loading and the choice between a drained and an undrained analysis. Few other soil parameters vary over such a wide range, and few are measured with as much scatter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Permeability is therefore estimated as an order of magnitude and a direction, not as a single precise number.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is the Coefficient of Permeability?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The coefficient of permeability is reported in m\/s, although older sources often use cm\/s, a factor of 100 that causes frequent errors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Strictly, k depends on both soil and fluid. The pore structure alone is described by the intrinsic permeability K, in m\u00b2, related to k by k = K \u00b7 \u03b3w \/ \u03bc, where \u03bc is the dynamic viscosity of water. Because the fluid is almost always water, permeability and hydraulic conductivity are used interchangeably. Viscosity falls as temperature rises, so laboratory results are normally corrected to 20 \u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The main controls are the fine fraction, void ratio, fabric, saturation and discontinuities. A thin silt parting or a network of fissures can carry far more water than the intact matrix around it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Permeability is not a soil constant. It is a property of the soil mass, its structure and its stress state.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Darcy&#8217;s Law and Its Limits<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Darcy (1856) established the law from experiments on sand filters for the water supply of Dijon. The discharge velocity is proportional to the hydraulic gradient:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>v = k \u00b7 i<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where v is the discharge (Darcy) velocity (m\/s), k is the coefficient of permeability (m\/s) and i is the hydraulic gradient, the loss of total head per unit length of flow path (dimensionless).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The flow rate follows from the gross area:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q = k \u00b7 i \u00b7 A<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where Q is the rate of flow (m\u00b3\/s) and A is the total cross-sectional area normal to the flow, solids and voids together (m\u00b2).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Water travels only through the voids, so the mean seepage velocity is v \/ n, where n is the porosity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The law assumes laminar flow through a saturated, rigid medium. Bear (1972) places the limit of linear behaviour at a Reynolds number of the order of 1 to 10, exceeded only in very coarse gravel, rockfill and close to a pumped well. In unsaturated soil, air blocks part of the pore space and k falls sharply, so saturated values overstate flow above the water table.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/setaf2018.com\/wp-content\/uploads\/2026\/11\/coefficient-of-permeability-blog_body-1.webp\" alt=\"Field Permeability Test: an engineer pouring water into a cased borehole and timing the flow on site\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Values by Soil Type<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Published ranges help to check whether a measured value is plausible. The table converts the typical values given by Das (2010) for saturated soils from cm\/s to m\/s.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Soil type<\/th><th>Typical k (m\/s)<\/th><th>Drainage character<\/th><\/tr><\/thead><tbody><tr><td>Clean gravel<\/td><td>1 to 10\u207b\u00b2<\/td><td>Free draining; pore pressures dissipate as load is applied<\/td><\/tr><tr><td>Coarse sand<\/td><td>10\u207b\u00b2 to 10\u207b\u2074<\/td><td>Free draining under construction loading<\/td><\/tr><tr><td>Fine sand<\/td><td>10\u207b\u2074 to 10\u207b\u2075<\/td><td>Drains readily; rapid or cyclic loading can build pore pressure<\/td><\/tr><tr><td>Silty clay<\/td><td>10\u207b\u2075 to 10\u207b\u2077<\/td><td>Slow drainage; behaviour depends on loading rate<\/td><\/tr><tr><td>Clay<\/td><td>below 10\u207b\u2078<\/td><td>Practically impervious in the short term; undrained during construction<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The range spans more than eight orders of magnitude. Silts, not listed separately, generally fall between fine sand and silty clay.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These values describe intact, saturated material. Fissured clays, laminated clays and fills with coarse inclusions can show mass permeabilities well above the range for their soil type, and variations of an order of magnitude within one formation are not unusual.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Is Permeability Measured in the Laboratory?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Laboratory tests, covered by ISO 17892-11, measure k on a specimen under a controlled gradient. The result is precise for the specimen, but sample quality controls its meaning.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Constant Head Test<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The constant head test suits clean sands and gravels and is described in ASTM D2434. Water flows under a fixed head difference, and the volume collected over a measured time gives:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>k = V \u00b7 L \/ ( A \u00b7 h \u00b7 t )<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where V is the volume of water collected (m\u00b3), L is the specimen length between head measurement points (m), A is the specimen cross-sectional area (m\u00b2), h is the constant head difference (m) and t is the collection time (s).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In fine-grained soils the collected volume becomes too small to measure reliably.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Falling Head Test<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The falling head test suits fine sands, silts and some clays. A standpipe of small cross-section feeds the specimen, and the fall of water level is recorded with time:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>k = ( a \u00b7 L \/ ( A \u00b7 t ) ) \u00b7 ln ( h\u2081 \/ h\u2082 )<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where a is the standpipe cross-sectional area (m\u00b2), L is the specimen length (m), A is the specimen cross-sectional area (m\u00b2), t is the time between readings (s), and h\u2081 and h\u2082 are the heads at the start and end of that interval (m).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In a rigid-wall mould, water can bypass the specimen along the wall, and the effective stress is not controlled.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flexible-Wall Permeameter (ASTM D5084)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For clays and other low-permeability materials, ASTM D5084 specifies a flexible-wall permeameter. The specimen is enclosed in a membrane in a triaxial cell, and cell pressure seals the membrane against it, preventing side-wall leakage. Back pressure saturates the specimen, and the effective stress can match the field condition, which matters because k decreases as a clay consolidates.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Is Permeability Measured in the Field?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Field tests involve far more ground than any specimen, including the fissures and lenses that sampling misses. ISO 22282 covers the main tests.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Borehole Rising and Falling Head Tests<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The water level in a borehole or standpipe is suddenly raised or lowered, and its recovery is recorded. The recovery rate and a shape factor for the intake give k, using the time lag method and shape factors of Hvorslev (1951); ISO 22282-2 covers the procedure. The tests are quick but sample only the ground near the intake, and smear or casing leakage can bias the result.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pumping Tests<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Water is pumped from a well at a controlled rate while drawdown is recorded in surrounding observation wells. Steady-state results are interpreted with the Thiem (1906) equation and transient results with the Theis (1935) solution, under ISO 22282-4. A pumping test gives the mass permeability over tens of metres and is the most representative input for dewatering design, but it is costly and slow.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Packer (Lugeon) Tests<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In rock, a borehole section is isolated by inflatable packers and water is injected in pressure stages, as covered by ISO 22282-3. Lugeon (1933) defined one Lugeon as a water take of one litre per minute per metre of test section at 1 MPa. One Lugeon corresponds roughly to 10\u207b\u2077 m\/s in a homogeneous rock mass, but the conversion depends on fracture geometry and is approximate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Permeability From Correlations and From the Oedometer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For clean, uniform sands, Hazen proposed an indirect estimate:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>k = C \u00b7 D\u2081\u2080\u00b2<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where k is the coefficient of permeability, D\u2081\u2080 is the grain size at which 10 % of the soil by mass is finer and C is an empirical coefficient whose value depends on the units. With k in cm\/s and D\u2081\u2080 in mm, C is of the order of 1, although reported values vary between authors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For D\u2081\u2080 = 0.1 mm and C = 1, the formula gives 0.01 cm\/s, or 1 \u00d7 10\u207b\u2074 m\/s; halving D\u2081\u2080 to 0.05 mm cuts k fourfold, to 2.5 \u00d7 10\u207b\u2075 m\/s. The correlation was developed for loose, clean, uniform filter sands with D\u2081\u2080 roughly between 0.1 and 3 mm, not for silts, clays or well-graded soils. Carrier (2003) recommended the Kozeny\u2013Carman equation, which uses the full grading and void ratio, instead.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For fine-grained soils, k can be back-calculated from the <a href=\"https:\/\/setaf2018.com\/en\/post\/oedometer-consolidation-test\/\">oedometer test<\/a>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>k = cv \u00b7 mv \u00b7 \u03b3w<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where cv is the coefficient of consolidation (m\u00b2\/s), mv is the coefficient of volume compressibility (m\u00b2\/kN) and \u03b3w is the unit weight of water, taken as 9.81 kN\/m\u00b3.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For cv = 1.0 m\u00b2\/year (3.17 \u00d7 10\u207b\u2078 m\u00b2\/s) and mv = 0.5 m\u00b2\/MN (5 \u00d7 10\u207b\u2074 m\u00b2\/kN), the result is k \u2248 1.6 \u00d7 10\u207b\u00b9\u2070 m\/s. The value applies to that load increment only, because cv and mv change with stress, and it inherits the small size of the oedometer specimen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Comparing the Methods<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The choice depends on soil type, problem scale and investigation budget.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Method<\/th><th>Scale<\/th><th>Particularly suited to<\/th><th>Main limitation<\/th><\/tr><\/thead><tbody><tr><td>Constant head test<\/td><td>Laboratory specimen<\/td><td>Clean sands and gravels<\/td><td>Misses field fabric; reconstituted specimens<\/td><\/tr><tr><td>Falling head test (rigid wall)<\/td><td>Laboratory specimen<\/td><td>Fine sands and silts<\/td><td>Side-wall leakage; stress not controlled<\/td><\/tr><tr><td>Flexible-wall test (ASTM D5084)<\/td><td>Laboratory specimen<\/td><td>Clays and low-permeability materials<\/td><td>Too small to include fissures and laminations<\/td><\/tr><tr><td>Borehole rising or falling head test<\/td><td>Ground around the intake<\/td><td>Profiling at several depths<\/td><td>Sensitive to smear and seal quality<\/td><\/tr><tr><td>Pumping test<\/td><td>Aquifer over tens of metres<\/td><td>Dewatering design<\/td><td>Cost, duration, water disposal<\/td><\/tr><tr><td>Packer (Lugeon) test<\/td><td>Rock mass along a test section<\/td><td>Fractured rock and grouting<\/td><td>Approximate conversion to k<\/td><\/tr><tr><td>Hazen correlation<\/td><td>Grading curve<\/td><td>Clean, uniform sands<\/td><td>Unreliable for fine or well-graded soils<\/td><\/tr><tr><td>Oedometer back-calculation<\/td><td>Laboratory specimen<\/td><td>Clays with only consolidation data<\/td><td>Stress-dependent; misses fabric drainage<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Why Do Laboratory and Field Values Differ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Laboratory and field results for the same deposit commonly disagree, usually with the field value higher, because each test samples something different.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The first cause is scale. A specimen a few centimetres high rarely contains the fissures, root holes, sand partings and lenses that control flow in the ground. Rowe (1972) showed that soil fabric governs drainage in many natural clays and that field permeability can exceed laboratory values by an order of magnitude or more.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The second cause is stratification. For flow parallel and perpendicular to a series of layers:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>kh = \u03a3 ( ki \u00b7 hi ) \/ H<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>kv = H \/ \u03a3 ( hi \/ ki )<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where kh and kv are the equivalent horizontal and vertical permeabilities (m\/s), ki and hi are the permeability (m\/s) and thickness (m) of layer i, and H is the total thickness (m).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Horizontal flow follows the most permeable layers and vertical flow is limited by the least permeable. For 10 m of clay with k = 10\u207b\u2079 m\/s containing sand partings with k = 10\u207b\u2075 m\/s and a total thickness of 0.5 m, kh is about 5.0 \u00d7 10\u207b\u2077 m\/s and kv about 1.05 \u00d7 10\u207b\u2079 m\/s, a ratio of roughly 480. A vertical tube sample measures something close to kv, while a borehole or pumping test is dominated by kh.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Remoulding that destroys fabric and air trapped by incomplete saturation lower laboratory values, while borehole smear lowers field values.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A laboratory k describes the specimen. A field k describes the ground, including everything the specimen left out.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Where Does Permeability Enter Design?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The commonest use is the rate of <a href=\"https:\/\/setaf2018.com\/en\/post\/foundation-settlement-analysis\/\">consolidation settlement<\/a>. The time to a given degree of consolidation is t = Tv \u00b7 Hdr\u00b2 \/ cv, where Tv is the time factor and Hdr the drainage path length, and cv = k \/ ( mv \u00b7 \u03b3w ). With mv unchanged, halving k doubles the time. A sand parting that halves the drainage path cuts the time fourfold.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For an <a href=\"https:\/\/setaf2018.com\/en\/post\/groundwater-excavation-support-design\/\">excavation below the groundwater table<\/a>, inflow is directly proportional to k, so an order-of-magnitude error in k becomes an order-of-magnitude error in pump capacity and discharge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Permeability also governs base stability. Upward flow beneath a <a href=\"https:\/\/setaf2018.com\/en\/post\/sheet-pile-wall-design\/\">sheet pile wall<\/a> reduces effective stress at formation level, and a confined permeable layer below a clay base can lift it where water pressure exceeds overburden. EN 1997-1 (Eurocode 7) treats these as the HYD and UPL limit states.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, k informs the choice between drained and undrained analysis, together with drainage path and loading rate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When Is a Single k Value Not Appropriate?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A single isotropic k suits only a reasonably homogeneous deposit with uniform drainage. Layered and laminated deposits need separate horizontal and vertical values, as the example above shows.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Permeability also changes with stress. As a clay consolidates, its void ratio falls and k with it; Tavenas et al. (1983) found that log k decreases approximately linearly with void ratio in natural soft clays.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fissured clays and fractured rock carry most flow in the discontinuities, and partially saturated soils have a k that depends on suction. In these cases the engineer works with a range, checks the design against both bounds and favours field measurements over correlations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Errors in Permeability Assessment<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Error<\/th><th>Consequence<\/th><\/tr><\/thead><tbody><tr><td>Designing dewatering from small laboratory specimens<\/td><td>Inflow underestimated; pumps undersized<\/td><\/tr><tr><td>Applying the Hazen formula to silty or well-graded soils<\/td><td>Estimate with no reliable indication of its error<\/td><\/tr><tr><td>Using one isotropic k in a laminated deposit<\/td><td>Horizontal inflow underestimated or vertical drainage overstated<\/td><\/tr><tr><td>Ignoring sand partings and fissures in clay<\/td><td>Consolidation predicted far slower than observed<\/td><\/tr><tr><td>Confusing cm\/s and m\/s<\/td><td>Factor of 100 error in every flow and time result<\/td><\/tr><tr><td>Testing clay in a rigid-wall mould without saturation control<\/td><td>Side-wall leakage or trapped air gives an unrepresentative k<\/td><\/tr><tr><td>Taking oedometer-derived k as a field value<\/td><td>Settlement predicted to develop too slowly<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Where SETAF2018 Fits<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SETAF2018 treats permeability as part of the material record of each soil layer rather than as a number on a test sheet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the Physical Properties tab, vertical permeability kv and horizontal permeability kh are defined separately for each material, alongside the index properties and unit weights. Keeping the two directions apart makes the assumed anisotropy visible to anyone reviewing the <a href=\"https:\/\/setaf2018.com\/en\/soil-profile\/\">soil profile<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Mechanical Properties tab holds the consolidation parameters: the coefficient of volume compressibility mv, the coefficient of consolidation calculated from t50 and from t90, and a separately defined horizontal coefficient of consolidation ch. The laboratory module evaluates the consolidation test itself, deriving the preconsolidation pressure, Cc and Cr by the Casagrande method and the time readings by the logarithmic and square-root methods.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Settlement\u2013time behaviour follows Terzaghi&#8217;s one-dimensional consolidation theory. In line with Annex F of EN 1997-1, the estimate draws on consolidation test parameters and on permeability coefficients obtained from field tests. The drainage conditions of each layer set the number of drainage paths, and the settlement\u2013time curve can be corrected for the construction period using the Terzaghi correction. The settlement tables and graph can be added to the geotechnical report.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The program does not perform groundwater flow or seepage analysis, design dewatering systems or interpret pumping tests. Excavation inflow, base heave under upward flow and drawdown around wells remain separate calculations based on measured heads and field permeability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Within those limits, the permeability, consolidation and drainage inputs that control settlement with time are held in one model, and the consolidation test data behind them can be processed in the <a href=\"https:\/\/setaf2018.com\/en\/laboratory-experiments\/\">laboratory testing<\/a> module of SETAF2018.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What is the coefficient of permeability?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It is the rate of water flow through a saturated soil under a unit hydraulic gradient. As the constant k in Darcy&#8217;s law, v = k \u00b7 i, it ranges from about 1 m\/s in clean gravel to below 10\u207b\u2078 m\/s in intact clay.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between permeability and hydraulic conductivity?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">None in routine geotechnical practice, where both mean k in m\/s for water. Strictly, hydraulic conductivity depends on the fluid, while intrinsic permeability, in m\u00b2, describes the pore structure alone; the two are linked through fluid unit weight and viscosity.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is a typical permeability for clay?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Below about 10\u207b\u2078 m\/s for intact clay, according to Das (2010), with silty clays between about 10\u207b\u2075 and 10\u207b\u2077 m\/s. Fissured or laminated clays can show much higher mass permeability.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">When is the constant head test used instead of the falling head test?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For coarse-grained soils with high permeability, such as clean sands and gravels, where a measurable volume of water passes in a practical time. Where flow is slower, the falling head test or a flexible-wall test to ASTM D5084 is used.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why is field permeability usually higher than laboratory permeability?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because field tests include fissures, sand partings and laminations that small specimens miss, and Rowe (1972) showed that fabric often controls drainage in natural clays. Sampling disturbance and incomplete saturation also lower laboratory values.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can permeability be estimated from grain size?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes, for clean, uniform sands. Hazen&#8217;s formula, k = C \u00b7 D\u2081\u2080\u00b2, gives an order-of-magnitude estimate from the effective grain size. It is unreliable for silts, clays and well-graded soils, where the Kozeny\u2013Carman equation or a direct test is preferable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How does permeability affect consolidation time?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Directly. The coefficient of consolidation equals k \/ ( mv \u00b7 \u03b3w ), and consolidation time is inversely proportional to cv, so with mv unchanged, halving k doubles the time. The drainage path has a stronger effect, since time scales with its square.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the ratio of horizontal to vertical permeability?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It depends on the deposit. Homogeneous soils have a ratio close to one, while layered and laminated deposits can reach tens to hundreds, because horizontal flow follows the most permeable layers. Measuring both directions is preferable to assuming a ratio.<\/p>\n\n\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the coefficient of permeability?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is the rate of water flow through a saturated soil under a unit hydraulic gradient. As the constant k in Darcy's law, v = k \u00b7 i, it ranges from about 1 m\/s in clean gravel to below 10\u207b\u2078 m\/s in intact clay.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between permeability and hydraulic conductivity?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"None in routine geotechnical practice, where both mean k in m\/s for water. Strictly, hydraulic conductivity depends on the fluid, while intrinsic permeability, in m\u00b2, describes the pore structure alone; the two are linked through fluid unit weight and viscosity.\"}}, {\"@type\": \"Question\", \"name\": \"What is a typical permeability for clay?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Below about 10\u207b\u2078 m\/s for intact clay, according to Das (2010), with silty clays between about 10\u207b\u2075 and 10\u207b\u2077 m\/s. Fissured or laminated clays can show much higher mass permeability.\"}}, {\"@type\": \"Question\", \"name\": \"When is the constant head test used instead of the falling head test?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"For coarse-grained soils with high permeability, such as clean sands and gravels, where a measurable volume of water passes in a practical time. Where flow is slower, the falling head test or a flexible-wall test to ASTM D5084 is used.\"}}, {\"@type\": \"Question\", \"name\": \"Why is field permeability usually higher than laboratory permeability?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Because field tests include fissures, sand partings and laminations that small specimens miss, and Rowe (1972) showed that fabric often controls drainage in natural clays. Sampling disturbance and incomplete saturation also lower laboratory values.\"}}, {\"@type\": \"Question\", \"name\": \"Can permeability be estimated from grain size?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, for clean, uniform sands. Hazen's formula, k = C \u00b7 D\u2081\u2080\u00b2, gives an order-of-magnitude estimate from the effective grain size. It is unreliable for silts, clays and well-graded soils, where the Kozeny\u2013Carman equation or a direct test is preferable.\"}}, {\"@type\": \"Question\", \"name\": \"How does permeability affect consolidation time?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Directly. The coefficient of consolidation equals k \/ ( mv \u00b7 \u03b3w ), and consolidation time is inversely proportional to cv, so with mv unchanged, halving k doubles the time. The drainage path has a stronger effect, since time scales with its square.\"}}, {\"@type\": \"Question\", \"name\": \"What is the ratio of horizontal to vertical permeability?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It depends on the deposit. Homogeneous soils have a ratio close to one, while layered and laminated deposits can reach tens to hundreds, because horizontal flow follows the most permeable layers. Measuring both directions is preferable to assuming a ratio.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>How the coefficient of permeability is measured \u2014 constant head, falling head and field tests \u2014 with typical values and why laboratory and field k differ.<\/p>\n","protected":false},"author":1,"featured_media":2028,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Coefficient of Permeability: Test Methods, Typical Values and Uses","rank_math_description":"How the coefficient of permeability is measured \u2014 constant head, falling head and field tests \u2014 with typical values and why laboratory and field k differ.","rank_math_focus_keyword":"coefficient of permeability"},"categories":[51],"tags":[],"class_list":["post-2035","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-soil-parameters"],"_links":{"self":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/2035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/comments?post=2035"}],"version-history":[{"count":0,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/posts\/2035\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/media\/2028"}],"wp:attachment":[{"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/media?parent=2035"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/categories?post=2035"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/setaf2018.com\/en\/wp-json\/wp\/v2\/tags?post=2035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}