MSE Wall Design: Tensile Rupture, Pullout and External Stability

How MSE walls are designed — tensile rupture, pullout and external stability — and why the reinforcement type changes the lateral stress that is assumed.
MSE Wall Design: a mechanically stabilized earth wall with precast concrete facing panels beside a highway ramp

A mechanically stabilized earth (MSE) wall is a retaining structure built from compacted granular fill and horizontal layers of tensile reinforcement, connected to a facing, that together behave as a coherent gravity mass. The reinforcement is either metallic, as steel strips, bar mats or welded wire grids, or geosynthetic, as geogrids and geotextiles.

MSE Wall Design: a mechanically stabilized earth wall with precast concrete facing panels beside a highway ramp

The wall is constructed from the bottom up. Each lift of fill is compacted over a layer of reinforcement, so soil and reinforcement are assembled together rather than one being drilled into the other.

For the designer, three groups of checks follow: the internal stability of each reinforcement layer, the external stability of the reinforced block as a whole, and the global stability of the ground around it. The lateral stress assumed for internal design depends on the reinforcement type, and that choice changes the required strength, spacing and length.

An MSE wall is designed as reinforced soil first and as a gravity wall second, and both have to work.

What Is a Mechanically Stabilized Earth Wall?

The concept was developed by Vidal in France in the 1960s as Reinforced Earth, using steel strips and a segmental facing. The term now covers any wall in which reinforcement within select fill resists earth pressure from inside the soil mass, rather than through the weight or stiffness of a structural wall.

FHWA-NHI-10-024 (Berg, Christopher and Samtani, 2009) limits the reinforced fill to 15 per cent fines passing the 0.075 mm sieve and a plasticity index of 6, with electrochemical limits where steel is used. Reinforcement length is at least 0.7H and not less than 2.4 m, where H is the design height. The facing, usually precast panels, modular blocks, welded wire or a wrapped geosynthetic, retains the fill and carries the reinforcement load at the connection.

Compared with the cantilever and gravity walls of conventional retaining wall design, an MSE wall tolerates much larger differential settlement, because a reinforced soil mass behind a jointed facing deforms without structural cracking.

How Does an MSE Wall Carry Load?

Under its own weight and any surcharge, the compacted fill tends to expand laterally. The reinforcement restrains it by developing tension, taken from the soil through friction and, for grids, passive bearing on transverse members.

The tension peaks some distance behind the facing. The locus of these peaks, the line of maximum tension, separates an active zone near the face from a resistant zone behind it, in which the reinforcement is anchored.

Its position depends on reinforcement stiffness. Reinforcement is inextensible when its deformation at failure is much smaller than that of the soil, as for steel, and extensible when it is comparable or larger, as for polymers. For inextensible reinforcement FHWA-NHI-10-024 uses a bilinear line starting at the toe and lying 0.3H behind the face over the upper half of the wall. For extensible reinforcement behind a vertical face it is the Rankine plane at 45° + φ′/2 to the horizontal.

Soil Reinforcement: ribbed steel strips and geogrid laid on compacted fill behind MSE wall facing panels during construction

How Is Internal Stability Checked?

At every reinforcement level, the maximum tensile force is estimated from the lateral stress in the fill and compared with tensile, pullout and connection resistance.

The lateral stress at the level of a reinforcement layer is:

σh = Kr · σv

where σh is the horizontal stress (kPa), Kr the lateral earth pressure coefficient of the reinforced zone (dimensionless) and σv the vertical stress (kPa), taken in the Simplified Method as γr · Z + q, with γr the reinforced fill unit weight (kN/m³), Z the depth below the top of the wall (m) and q a uniform surcharge (kPa).

The maximum tensile force follows from the spacing:

Tmax = σh · Sv

where Tmax is the maximum tensile force per unit width (kN/m) and Sv the tributary vertical spacing (m).

Tensile Rupture

Tmax must not exceed the factored long-term strength multiplied by the coverage ratio Rc, the reinforcement width divided by its horizontal spacing. For steel, the yield strength acts on the section left after a sacrificial corrosion thickness over the design life, normally 75 years for permanent walls and 100 years for abutments. For geosynthetics, three reduction factors apply:

Tal = Tult / ( RFID · RFCR · RFD )

where Tal is the long-term tensile strength per unit width of reinforcement (kN/m), Tult the ultimate wide-width tensile strength, from ASTM D6637 for geogrids and ASTM D4595 for geotextiles (kN/m), and RFID, RFCR and RFD the dimensionless reduction factors for installation damage, creep and durability.

Pullout

Beyond the line of maximum tension, FHWA-NHI-10-024 gives the pullout resistance as:

Pr = F* · α · σ′v · Le · C · Rc

where Pr is the pullout resistance per unit width (kN/m), σ′v the effective vertical stress at the reinforcement level (kPa) and Le the embedment length in the resistant zone (m), while F* is the pullout resistance factor, α a scale effect correction factor, C the effective unit perimeter, equal to 2 for strips, grids and sheets, and Rc the coverage ratio, all dimensionless.

Without test data, defaults apply. For ribbed steel strips F* is 1.2 + log Cu at the top, not more than 2.0, decreasing to tan φr at 6 m, where Cu is the coefficient of uniformity and φr the friction angle of the fill; for geosynthetics it is 0.67 tan φr. The factor α is 1.0 for steel and defaults to 0.8 for geogrids and 0.6 for geotextiles.

Live load surcharge is excluded from σ′v in this check, and Le may not be less than 0.9 m. Pullout tends to govern in the upper layers, where overburden is small.

Connection Strength

The Simplified Method takes the force at the facing connection equal to Tmax for all reinforcement types. Steel connection hardware is designed for that force with the same corrosion allowance as the reinforcement.

For geosynthetics in modular blocks, the connection is usually frictional and tested. Its capacity depends on the weight of blocks above, so it is lowest near the top, where a layer that passes rupture and pullout can still fail at the face.

Simplified Method vs Coherent Gravity Method

Both methods in FHWA-NHI-10-024 estimate Kr and σv; they differ in scope and in the vertical stress.

The Coherent Gravity Method grew out of steel-strip Reinforced Earth walls and applies to inextensible reinforcement only. The coefficient varies from K₀ at the top to Ka at 6 m depth, and vertical stress at each level follows the Meyerhof distribution of the reinforced mass above it.

The Simplified Method of Allen et al. (2001) covers all reinforcement types. Vertical stress is the overburden γr · Z + q, and Kr is a multiple of Ka that depends on the reinforcement. Ka uses the friction angle of the reinforced fill, by Rankine for a vertical face and by Coulomb for a battered one, as set out under earth pressure coefficients.

Reinforcement typeKr / Ka at top of wallKr / Ka at 6 m depth and below
Metallic strips1.71.2
Metal bar mats and welded wire grids2.51.2
Geogrids and geotextiles1.01.0

The ratio varies linearly over the top 6 m. FHWA-NHI-10-024 treats the Simplified Method as standard and retains the Coherent Gravity Method as an alternative for steel-reinforced walls.

For a fill with φr = 34° and γr = 19 kN/m³, Ka = tan² ( 45° − 34°/2 ) = 0.283. At 3 m depth with no surcharge, σv = 57 kPa. With steel strips Kr / Ka = 1.45 at that depth, so σh = 23.4 kPa and, at Sv = 0.75 m, Tmax = 17.5 kN/m. With a geogrid in the same fill, σh = 16.1 kPa and Tmax = 12.1 kN/m, so the steel layer carries about 45 per cent more force.

External Stability: Sliding, Overturning and Bearing

For external stability the reinforced zone is a rigid block of length L and height H. The thrust behind it uses the active coefficient Kab and unit weight γb of the retained fill: ½ · Kab · γb · H² from the soil and Kab · q · H from a uniform surcharge.

Sliding resistance is the vertical load times the tangent of the lowest friction angle along the base: the reinforced fill, the foundation soil or, for a continuous geosynthetic base layer, the interface. Live load over the reinforced zone is excluded from the resisting forces.

Overturning about the toe, checked with a factor of safety in allowable stress design, is replaced in load and resistance factor design by a limit on the eccentricity of the resultant, stricter on soil than on rock. Bearing is then checked with the vertical stress spread uniformly over an effective width, following Meyerhof:

σv = V / ( L − 2e )

where σv is the equivalent uniform vertical stress at the base of the reinforced zone (kPa), V the sum of vertical forces per unit width, including live load surcharge in this check (kN/m), L the reinforcement length at the base (m) and e the eccentricity of the resultant from the centre of the base (m).

The wall is embedded at least H/20 below horizontal ground at the toe, and never less than 0.6 m. On a weak foundation, external stability often fixes the reinforcement length before the internal checks do.

Global and Compound Stability

Global slip surfaces pass behind and beneath the reinforced zone, so conventional limit equilibrium applies; the choice of method is discussed in Fellenius vs Bishop. Compound surfaces pass partly through the reinforced zone, and each layer they cross contributes the lesser of its rupture and pullout resistance beyond the surface.

On soft foundations global stability often governs, and longer reinforcement does little for a surface beneath the block; ground improvement or lightweight fill does more.

CheckFailure modeGoverned by
Tensile ruptureReinforcement breaks at the line of maximum tensionLong-term strength, Kr, vertical spacing
PulloutReinforcement slides out of the resistant zoneF*, embedment length, effective overburden
ConnectionReinforcement separates from the facingHardware capacity or tested connection strength
SlidingBlock slides on its baseLowest base friction angle, retained thrust
EccentricityResultant moves too far from the base centreL / H ratio, retained thrust
BearingFoundation fails beneath the blockStress over L − 2e, foundation strength
Global and compoundSlip surface beneath or through the structureFoundation strength, reinforcement crossed

Comparing MSE Walls With Soil Nail Walls

Finished, the two look alike: a face, rows of tensile elements and a reinforced block. They are built in opposite directions.

An MSE wall is built, a soil nail wall is excavated. The difference decides which stress state the reinforcement sees.

MSE reinforcement sits in compacted fill, so compaction stresses are locked in from the first lift. A soil nail wall reinforces existing ground excavated top down; the ground unloads and nails develop force only as the face moves, as described in soil nail wall design.

FeatureMSE wallSoil nail wall
Construction sequenceBottom up, in compacted liftsTop down, in excavated lifts
Soil reinforcedImported select granular fillExisting ground in place
ReinforcementStrips, grids or geosynthetics laid horizontallyGrouted steel bars drilled at an inclination
Stress stateCompaction-induced, set by KrExcavation-induced stress relief
FacingPanels, blocks or wrap, connected as fill risesShotcrete applied lift by lift
Typical settingEmbankments, ramps, bridge abutmentsExcavations and slope cuts
Design referenceFHWA-NHI-10-024 (Berg, Christopher and Samtani, 2009)FHWA-NHI-14-007 (Lazarte et al., 2015)

Both check rupture, pullout, facing and global stability, but MSE pullout relies on controlled fill and default F* values, while nail pullout depends on bond in natural ground and is verified by testing.

Why Do Metallic and Geosynthetic Reinforcement Give Different Designs?

The difference is strain compatibility. Steel reaches working load at very small strain, so the fill cannot deform enough to reach the active state and lateral stress near the top stays close to at-rest, raised by compaction. Geosynthetics stretch more, and lateral stress falls towards Ka.

The lateral stress in an MSE wall is not a property of the fill alone. It is set by how far the reinforcement lets the fill move.

The failure zone follows: a bilinear line for steel, the Rankine plane for geosynthetics, and different pullout lengths at the same height. Long-term, steel loses section to corrosion while polymers creep and suffer installation damage. Instrumented geosynthetic walls have also shown loads well below limit equilibrium predictions, which led Allen et al. (2003) to propose the K-Stiffness Method.

Neither type is inherently superior. Steel suits tall walls and heavy surcharges in controlled fill; geosynthetics suit environments aggressive to steel.

When Is an MSE Wall Not Appropriate?

The main limit is geometric. The reinforced zone is at least 0.7H wide, and in a cut it must be excavated and rebuilt in select fill. Where the ground behind must stay, because of a property line or an existing structure, a soil nail or anchored wall works with the ground instead. Shored MSE walls against a stable cut exist but remain specialist.

Water is the second limit. The reinforced zone is designed as drained, so a submerged wall or one facing rapid drawdown needs free-draining fill and a hydrostatic load case; submergence also lowers the stress on which pullout depends.

The third is the environment. Steel exposed to deicing salts, stray currents or aggressive groundwater corrodes faster than a standard allowance assumes, and utility trenches through the reinforced zone sever the anchorage of every layer they cross.

Common Errors in MSE Wall Design

ErrorConsequence
Using Kr = Ka for steel reinforcement in the upper 6 mTmax at the top is 1.7 times the assumed value for strips and 2.5 times for grids
Counting traffic surcharge in σ′v for pulloutPullout resistance overstated in the layers where it governs
Designing the connection for less than TmaxUpper layers fail at the facing despite passing rupture and pullout
Retained thrust calculated with reinforced fill propertiesExternal thrust underestimated where the retained soil is weaker
Omitting global and compound stabilityDeep-seated failure through a soft foundation not identified
Specifying fill without electrochemical limits for steelCorrosion exceeds the sacrificial allowance before the design life ends
No drainage behind or beneath the reinforced zoneWater pressure the wall was never designed for

Where SETAF2018 Fits

Programs written for MSE walls carry the Kr / Ka profiles, reduction factors, default pullout parameters and connection data these checks require, and reinforcement sizing belongs in those tools. Reinforcement sizing for MSE walls is outside the scope of SETAF2018.

The calculations it does perform sit beside the MSE problem, on the excavation side. Soil nails are defined within a wall section by depth, horizontal spacing, inclination, bar diameter, drilled diameter and length, with soil–grout bond resistance taken from user-defined values, empirical data, effective stress or total stress parameters, or pull-out test results. Steel strand anchors in the same wall model are checked for grout–soil bond, tendon tensile failure and tendon–grout bond, and for internal stability through a block analysis at every construction stage.

The wall analysis uses the Dependent Pressures Method with Rankine or Coulomb earth pressures, so the pressure on the wall follows its displacement between the at-rest, active and passive states.

Slope stability is evaluated by limit equilibrium with the OMS/Fellenius and simplified Bishop methods, on circular or polygonal slip surfaces with an optimisation search, including anchors, soil nails and surcharge loads. A nail contributes the lesser of its pullout resistance behind the slip surface and its tendon rupture load, the pairing described above for MSE reinforcement; geogrid and steel strip layers are not among the reinforcement types.

In SETAF2018, the External Stability command transfers a wall section to the slope analysis screen and Save to Wall stores the result with that wall, so the global check uses the wall’s own geometry. Local reports print the equations with the input values.

Nailed and anchored walls are designed in the excavation support module, with global checks in the module for slope stability.

Frequently Asked Questions

What is an MSE wall?

It is a retaining wall of compacted granular fill and horizontal layers of steel or geosynthetic reinforcement connected to a facing. The reinforcement restrains lateral expansion of the fill, so the reinforced zone acts as a gravity block resisting the soil behind it.

What is the difference between an MSE wall and a soil nail wall?

The construction direction. An MSE wall is built bottom up in compacted imported fill, so its reinforcement carries compaction-induced stress from the start. A soil nail wall is excavated top down, reinforcing existing ground with grouted bars that develop force only as the face moves.

What is the minimum reinforcement length for an MSE wall?

It is 0.7H and not less than 2.4 m under FHWA-NHI-10-024, where H is the design height. Sloping backfill, concentrated surcharges or weak foundations often require more, because external or global stability governs.

What is the coherent gravity method?

It is an internal stability method for steel-reinforced walls. The lateral stress coefficient varies from K₀ at the top to Ka at 6 m depth, vertical stress follows the Meyerhof distribution, and pullout is checked behind a bilinear line of maximum tension.

Which failure modes are checked in internal stability?

Three: tensile rupture of the reinforcement, pullout from the resistant zone behind the line of maximum tension, and failure of the facing connection. Each is checked at every level against the maximum tensile force from lateral stress and vertical spacing.

Why is global stability checked separately?

Because the critical slip surface may pass beneath the reinforced zone, where reinforcement contributes nothing. Internal and external checks treat the wall and its base; global and compound analyses examine the foundation and slope, which often govern on soft ground.

Can MSE walls be used in excavations?

Rarely in the standard form. The reinforced zone must be at least 0.7H wide, so the ground behind the face has to be removed and rebuilt in select fill. Where it must remain, soil nail or anchored walls are usual.

How does reinforcement type affect lateral stress?

Directly. Stiff steel limits soil movement, so lateral stress near the top stays above active; the Simplified Method uses Kr / Ka of 1.7 for strips and 2.5 for grids at the top, reducing to 1.2 at 6 m. Extensible geosynthetics allow the fill to reach Ka throughout.

Share:

More Posts

WHATSAPP Global Support Team