The relative density of sand is a measure of how tightly a granular soil is packed in the ground compared with the loosest and densest states the same soil reaches in standard laboratory tests. It is written Dr, or ID when called the density index, and nominally runs from zero to 100 per cent.

Nearly every engineering property of a clean sand follows it. Peak friction angle, stiffness, dilatancy and resistance to cyclic loading all increase as the packing becomes denser, and the terms on a borehole log, from very loose to very dense, are defined against it.
Measuring it is another matter. The calculation needs the void ratio of the sand in the ground, and clean sand cannot be sampled without changing that void ratio. In practice the value is inferred from a penetration test through one correlation and converted into a design parameter through another.
Relative density is rarely a measurement. It is an intermediate variable carried between two correlations.
What Is Relative Density?
It is the position of the in-place void ratio within the range of void ratios a particular sand can occupy:
Dr = ( emax − e ) / ( emax − emin )
where e is the in-place void ratio, emax is the maximum index void ratio of the loosest standard state and emin is the minimum index void ratio of the densest standard state. The result is a fraction, usually reported as a percentage.
Because void ratio is rarely measured directly, the same definition is often written in terms of dry unit weight:
Dr = [ γd,max · ( γd − γd,min ) ] / [ γd · ( γd,max − γd,min ) ]
where γd is the in-place dry unit weight and γd,max and γd,min are the maximum and minimum index dry unit weights, all in kN/m³.
In both forms the reference states belong to the soil being tested. The same void ratio can describe a dense state in one sand and a loose state in another, depending on grading and particle shape, which is why the descriptive terms are tied to relative density rather than to void ratio. ISO 14688-2 calls the same quantity the density index, ID.
How Are emax and emin Determined?
By two laboratory procedures on a disturbed sample of the same sand. ASTM D4253 determines the maximum index density by vibrating the soil in a mould on a vibratory table under a surcharge. ASTM D4254 determines the minimum index density by placing the dry soil as loosely as possible, by pouring through a funnel or by the tube method. Both are restricted to cohesionless, free-draining soils with up to 15 per cent passing the 75 µm sieve.
The word index matters. The limits are reproducible reference states, not physical bounds, and a sand compacted with heavy vibratory plant can reach a void ratio below the laboratory emin, giving a relative density above 100 per cent.
The definition is also sensitive, because the denominator is a small difference between two measured values. Where emax − emin is 0.30, an error of 0.03 in the in-place void ratio shifts the relative density by ten percentage points.

Descriptive Terms: Very Loose to Very Dense
The descriptive scale divides relative density into five bands. Skempton (1986) associated each band with a range of normalised blow counts:
| Descriptor | Dr (%) | Typical (N1)60 |
|---|---|---|
| Very loose | 0–15 | 0–3 |
| Loose | 15–35 | 3–8 |
| Medium dense | 35–65 | 8–25 |
| Dense | 65–85 | 25–42 |
| Very dense | 85–100 | 42–58 |
The relative density boundaries match the density index scale of ISO 14688-2. The blow counts are (N1)60 values, not raw counts from the log, and at the loose end a few blows separate very loose from medium dense, which is within the scatter of the test.
Estimating Relative Density From the SPT
Because clean sand cannot be sampled intact without methods such as ground freezing, the standard penetration test is the usual route. Each correlation below was calibrated against a particular corrected form of the blow count, and the SPT corrections that produce N60 and (N1)60 are a prerequisite.
Skempton (1986)
Skempton reviewed field and laboratory data and found that, for normally consolidated sands, the normalised blow count increases approximately with the square of relative density:
( N1 )60 / Dr² ≈ 60
where (N1)60 is the blow count corrected to 60 per cent hammer energy and normalised to one atmosphere of vertical effective stress, and Dr is relative density as a fraction.
Rearranged, Dr = √( (N1)60 / 60 ), so an (N1)60 of 20 gives about 58 per cent. The constant is not universal: Skempton showed that it increases with particle size, age and overconsolidation, and that freshly deposited sands, including chamber sands, give lower values.
Meyerhof (1957)
Meyerhof fitted an expression to the calibration chamber tests of Gibbs and Holtz (1957), with overburden entering explicitly:
N = Dr² · ( 17 + 24 · σ′v / pa )
where N is the blow count, Dr is relative density as a fraction, σ′v is the vertical effective stress and pa is atmospheric pressure, approximately 100 kPa.
At one atmosphere the bracket equals 41, well below Skempton’s 60. Skempton (1986) linked much of the difference to ageing, since chamber sand is freshly deposited. The relationship also predates routine hammer energy measurement, so its blow counts carry no stated energy ratio.
Kulhawy and Mayne (1990)
Kulhawy and Mayne replaced Skempton’s single constant with factors for the three effects he had identified:
( N1 )60 / Dr² = Cp · CA · COCR
where Cp = 60 + 25 · log D50 is the particle size factor with D50 in millimetres, CA = 1.2 + 0.05 · log ( t / 100 ) is the ageing factor with t in years, and COCR = OCR^( 0.18 ) is the overconsolidation factor.
Grain size is measurable, but the age and overconsolidation ratio of a sand deposit are usually estimates, so the refinement is only as good as those assumptions.
Estimating Relative Density From the CPT
The cone penetration test gives a continuous record that does not depend on hammer energy. Its relative density correlations come largely from calibration chamber tests on sand deposited at a controlled density; the work of Jamiolkowski et al. (1985) and Baldi et al. (1986) underlies most of them. Kulhawy and Mayne (1990) expressed the chamber data in a form parallel to their SPT relationship:
Dr² = qc1N / ( 305 · QC · QOCR · QA )
where qc1N = ( qc / pa ) / ( σ′v / pa )^( 0.5 ) is the cone resistance qc normalised for overburden, QC is a factor for the compressibility of the sand, QOCR = OCR^( 0.18 ) and QA = 1.2 + 0.05 · log ( t / 100 ), with t in years.
The chamber tests used mostly clean, uncemented, unaged quartz sands. Crushable or carbonate sands give lower cone resistance at the same density, so the correlation underestimates their relative density; aged or lightly cemented sands give higher resistance, so it overestimates it.
Comparing the Correlations
| Correlation | Input | Soil conditions | Main limitation |
|---|---|---|---|
| Index density tests | emax, emin, in-place e or γd | Clean sand, up to 15 per cent fines | In-place density only near the surface |
| Skempton (1986) | (N1)60 | Normally consolidated natural sands | One constant ignores grain size, age and stress history |
| Meyerhof (1957) | N and σ′v | Freshly deposited chamber sands | No stated energy ratio; no ageing effect |
| Kulhawy and Mayne (1990), SPT | (N1)60, D50, age, OCR | Clean sands of known grading | Age and OCR usually assumed |
| Kulhawy and Mayne (1990), CPT | qc, σ′v, compressibility, age, OCR | Clean quartz sands | Unreliable in crushable or cemented sands |
A worked comparison shows the scale of the differences. Take a clean sand with D50 = 0.3 mm, an (N1)60 of 20 and a vertical effective stress of 100 kPa. Skempton’s constant gives a relative density of about 58 per cent. Kulhawy and Mayne, for a normally consolidated deposit 1,000 years old, give a constant of about 58.7 and the same 58 per cent. With an overconsolidation ratio of 3 assumed instead, the constant rises to about 71.5 and the relative density falls to about 53 per cent. Meyerhof, with the blow count taken at face value at one atmosphere, gives about 70 per cent.
The same blow count gives between 53 and 70 per cent: three results describe a medium dense sand and the fourth a dense one.
Why Do the Correlations Disagree?
Because each summarises a different population of sands, and because the blow count responds to more than density.
Age is a major effect: sand deposits gain penetration resistance over time without measurable change in void ratio, so fresh chamber sand and natural deposits will always differ. Overconsolidation raises the horizontal stress, to which penetration resistance also responds, so a correlation that ignores stress history overestimates the relative density of an overconsolidated sand.
Grain size and fines act in opposite directions: coarser sands give higher blow counts at the same relative density and silty sands generally lower ones, which is one reason liquefaction procedures adjust the blow count for fines content.
The correction state is the easiest source to avoid: a raw count or an unnormalised N60 entered into a relationship built on (N1)60 produces an error invisible in the result.
A relative density derived from the SPT is not a property of the sand alone. It belongs to the sand, the correlation and the correction state of the blow count together.
How Relative Density Feeds Design
Relative density is rarely an end in itself; the question is whether passing through it adds information or only a step.
The friction angle of the soil is the most common target. Bolton (1986) expressed the peak friction angle as the critical state angle plus a dilatancy contribution governed by the relative dilatancy index IR = ID · ( 10 − ln p′ ) − 1, with ID as a fraction, p′ the mean effective stress in kPa and IR kept within the limits Bolton stated. In triaxial compression the peak angle exceeds the critical state angle by about 3 IR degrees. This explains why a dense sand at low stress mobilises a higher peak angle than the same sand at depth. The direct empirical route is covered in the article on SPT N value vs friction angle.
Stiffness follows density too, but many modulus correlations for sands use the corrected blow count directly, so a detour through relative density only adds scatter.
Liquefaction is the clearest case. Current triggering procedures, including TBDY 2018 Annex 16B, use (N1)60 adjusted for fines content, not relative density. The link still helps interpretation: among its screening conditions, TBDY 2018 treats coarse-grained soils with (N1)60 below 30 as potentially liquefiable, which under Skempton’s constant corresponds to a relative density of about 71 per cent. The liquefaction analysis itself does not pass through it.
Where a design method is calibrated directly on the blow count, converting to relative density first adds a correlation and removes nothing.
When Is Relative Density Not Appropriate?
When the soil does not behave as a clean, free-draining granular material.
Sands with more than about 15 per cent fines fall outside the index density standards, and plastic fines change behaviour more than grain packing does; fines content and plasticity are then more informative. Clays have no meaningful relative density; their state is described by consistency, undrained strength and overconsolidation ratio. In gravels the index tests need large moulds, and the SPT blow count reflects particles striking the sampler shoe rather than the resistance of the mass.
Cemented, carbonate, crushable and micaceous sands depart from the clean quartz sands behind the correlations: cementation raises penetration resistance without denser packing, and crushable grains lower it.
Common Errors in Using Relative Density
| Error | Consequence |
|---|---|
| Raw blow count used in a correlation built on (N1)60 | Relative density wrong by an unreported margin |
| Skempton’s constant of 60 applied to young fill or overconsolidated sand | Density underestimated in young fill, overestimated in overconsolidated sand |
| Chamber-based CPT correlation used in carbonate or cemented sand | Density under- or overestimated depending on grain behaviour |
| Relative density quoted for silty sand above 15 per cent fines | Value outside the scope of the reference tests |
| Value above 100 per cent rejected as impossible | Index limits mistaken for physical bounds |
| Relative density inserted between blow count and a parameter already correlated with it | Second correlation and its scatter added for no gain |
| Correlation and assumptions not stated in the report | Value cannot be reproduced or judged |
Where SETAF2018 Fits
SETAF2018 treats relative density as part of the material definition in the shared soil model rather than as a number held in a separate spreadsheet.
In the Physical Properties tab of each material, relative density Dr and fines content FC are defined alongside the unit weights, natural water content, Atterberg limits and void ratio. Void ratio, porosity, degree of saturation and the derived unit weights can be calculated with the Calculate button or entered directly. Relative density is entered as a material parameter rather than computed from the blow counts, so the correlation behind it remains the engineer’s choice and belongs in the report beside the value.
The blow counts are held in the In Situ tab. The SPT N value is entered at each test depth with the hammer efficiency Em and the correction factors Cb, Cs and Cr, and the Calculate button produces CN, N1, N60 and N1,60. The corrected values feed correlations such as the deformation modulus of coarse-grained soils, and the correction state of each blow count stays beside the raw count.
Fines content and corrected blow counts meet again in the liquefaction assessment. For sands and gravels, liquefaction is evaluated to TBDY 2018 Annex 16B from the SPT profile of the selected borehole, with the blow count adjusted for fines content as the code prescribes and post-liquefaction settlement estimated by Tokimatsu–Seed (1987).
Because borehole records, material parameters and analyses share one soil profile, the material parameters and corrected blow counts entered once are the same values every analysis on that borehole draws on. The calculation reports print the equations with their input values, so a reviewer can trace each corrected blow count from the field record into the liquefaction module.
Frequently Asked Questions
What is relative density?
It is the position of the in-place void ratio of a granular soil between its maximum and minimum index void ratios, expressed as a percentage from zero at the loosest standard state to 100 at the densest.
What is the difference between relative density and relative compaction?
The reference state differs. Relative density places the in-place density between the minimum and maximum index densities from pouring and vibratory tests. Relative compaction divides the field dry density by the maximum dry density from a Proctor test. The two are not interchangeable.
How are emax and emin measured?
In the laboratory, on a disturbed sample. ASTM D4253 obtains the maximum index density by vibrating the soil in a mould under a surcharge, and ASTM D4254 obtains the minimum index density by pouring the dry soil loosely. Both apply to free-draining soils with up to 15 per cent fines.
How is relative density estimated from SPT?
Through an empirical correlation with the corrected blow count. Skempton (1986) gives (N1)60 divided by Dr squared as approximately 60 for normally consolidated natural sands, and Kulhawy and Mayne (1990) adjust that constant for grain size, age and overconsolidation.
Why can relative density not be measured directly in most projects?
Because it needs the in-place void ratio, and clean sand cannot be sampled without disturbing it. Tube sampling densifies loose sand and loosens dense sand, intact samples require methods such as ground freezing, and in-place density tests reach only shallow depths.
What relative density is considered dense?
Between 65 and 85 per cent is described as dense, and above 85 per cent as very dense. Skempton (1986) associated the dense band with (N1)60 values of roughly 25 to 42, and ISO 14688-2 uses the same boundaries for the density index.
Does relative density apply to clays?
No. Relative density describes the packing of free-draining granular soils, and the index density tests are limited to soils with up to 15 per cent fines. The state of a clay is described by its consistency, undrained strength and overconsolidation ratio.
How does relative density affect liquefaction resistance?
Higher relative density increases liquefaction resistance, because dense sand tends to dilate under shear rather than contract and build excess pore pressure. Current procedures, including TBDY 2018 Annex 16B, express this through the corrected blow count adjusted for fines content.