Effective stress is the part of the total stress in a soil that is carried through the contacts between particles, equal to the total stress minus the pore water pressure. It controls compression, shear strength and stiffness, and almost every geotechnical calculation needs it before any other step can begin.

Total stress comes from the weight of everything above a point: soil, water and any applied load. Pore water pressure comes from the groundwater regime, which may be hydrostatic, artesian, perched or flowing. The two quantities are set by different things, which is why effective stress can change while the soil itself stays exactly the same.
For the engineer, the consequence is that the groundwater level is a design input as influential as any strength parameter. A water table that rises by one metre changes bearing capacity, settlement, liquefaction resistance and earth pressure without a single laboratory value being revised.
Soil carries load through two channels, and only one of them produces strength.
What Is Effective Stress?
A saturated soil is a skeleton of solid particles with water filling the voids. A load applied to it is shared between the two phases: part travels grain to grain through the contacts, and part is carried by the pressure in the pore water.
Water carries no shear stress. Shear resistance comes from friction and interlocking at the particle contacts, and it is proportional to the normal force pressing the particles together, so only the share of load carried by the skeleton can generate it. In effective stress terms the Mohr–Coulomb criterion reads τf = c′ + σ′ · tan φ′.
Effective stress is not the actual contact stress. It is an averaged quantity over the whole cross-section, and it governs the measurable behaviour of the soil.
Terzaghi’s Principle (1936)
Terzaghi developed the concept in his consolidation work of the 1920s and stated it in its classical form at the First International Conference on Soil Mechanics and Foundation Engineering in 1936. The principle has two parts. The first is a definition:
σ′ = σ − u
where σ′ is the effective stress (kPa), σ is the total stress on the plane considered (kPa) and u is the pore water pressure (kPa).
The second is a law: all measurable effects of a change of stress, including compression, distortion and a change of shearing resistance, are due exclusively to changes in effective stress. A rise in pore pressure under constant total stress therefore weakens the soil as surely as unloading it would.
Skempton (1960) showed that the simple form is accurate for saturated soils because the particles are far less compressible than the soil skeleton. Bishop (1959) proposed an extended form for unsaturated soils, discussed below.

How Is the Vertical Effective Stress Profile Calculated?
The calculation has three steps: total stress from the weight of the layers, pore pressure from the groundwater condition, and the difference between them. For horizontal layers the total vertical stress is:
σv = Σ γi · hi
where σv is the total vertical stress (kPa), γi is the unit weight of layer i (kN/m³) and hi is the thickness of layer i above the depth considered (m). The natural unit weight applies above the water table and the saturated unit weight below it.
Under hydrostatic conditions the pore pressure is the weight of the water column above the point:
u = γw · hw
where u is the pore water pressure (kPa), γw is the unit weight of water, taken as 9.81 kN/m³, and hw is the depth below the water table (m).
Consider three layers with the water table at 2 m, using unit weights assumed for illustration. Sand from 0 to 4 m has γ = 18 kN/m³ above the water table and γsat = 20 kN/m³ below it, clay from 4 to 10 m has γsat = 19 kN/m³, and dense sand from 10 to 15 m has γsat = 21 kN/m³. At 10 m the total stress is 18 · 2 + 20 · 2 + 19 · 6 = 190 kPa and the pore pressure 9.81 · 8 = 78.48 kPa.
| Depth (m) | Total stress σv (kPa) | Pore pressure u (kPa) | Effective stress σ′v (kPa) |
|---|---|---|---|
| 2 (water table) | 36.00 | 0 | 36.00 |
| 4 (sand / clay) | 76.00 | 19.62 | 56.38 |
| 10 (clay / sand) | 190.00 | 78.48 | 111.52 |
| 15 | 295.00 | 127.53 | 167.47 |
Summing submerged unit weights, γ′ = γsat − γw, gives the same answer and is a useful check: at 10 m, 36 + 2 · 10.19 + 6 · 9.19 = 111.52 kPa. The profile is linear within each layer and changes slope at the water table and at every layer boundary.
Pore Water Pressure Below the Water Table
The hydrostatic distribution is correct only when the water is static and connected to a single free surface. Three conditions cover most of what a borehole reveals.
Hydrostatic Conditions
Pore pressure is zero at the water table and increases at γw per metre. The piezometric level is the same at every depth, so there is no vertical flow.
Artesian Pressure
An artesian condition exists where a permeable layer is confined beneath a low-permeability layer and recharged from higher ground. Pore pressure in the confined layer exceeds the hydrostatic value, and a piezometer sealed into it shows water rising above the local water table, sometimes above the ground surface.
Suppose the lower sand in the example is confined by the clay, with its piezometric level 1 m above ground. The pore pressure at 10 m becomes 9.81 · 11 = 107.91 kPa, and the effective stress falls from 111.52 to 82.09 kPa, about 26 per cent lower. Water now seeps upward through the clay. The clay would reach the point of uplift, with zero effective stress at its base, if the piezometric level rose to about 9.4 m above ground.
Perched Water
A perched water table forms where infiltrating water is held above a lens of low permeability, with unsaturated soil beneath it. Treating a perched level as the regional water table overstates pore pressure below the lens; ignoring it misses the saturated zone above the lens.
| Groundwater condition | Pore pressure distribution | Typical setting |
|---|---|---|
| Hydrostatic | Zero at the water table, increasing at γw per metre | Permeable deposits with a stable water table |
| Artesian | Above hydrostatic in the confined layer | Sand or gravel aquifer beneath clay |
| Perched | Hydrostatic within the perched zone, discontinuous below | Clay lens within a granular deposit |
| Capillary | Negative above the water table | Silts and fine sands, shallow water table |
| Downward seepage | Below hydrostatic | Dewatering or pumping from a lower aquifer |
| Upward seepage | Above hydrostatic | Excavation base above an artesian layer |
What Happens Above the Water Table? Capillary Rise and Suction
Surface tension holds water above the free water surface in fine pores. Within the saturated capillary fringe the pore water is in tension, reaching −γw · hc at a height hc above the water table, and by Terzaghi’s equation a negative pore pressure adds to the effective stress. Capillary rise is negligible in gravel and can reach metres in silts and clays.
If the upper layer in the example were a silt with a saturated fringe 1 m thick, the pore pressure at 1 m depth would be −9.81 kPa and the effective stress 27.81 kPa instead of 18 kPa. At the water table the effective stress would be 38 kPa rather than 36 kPa, because the saturated fringe is heavier.
Above the fringe the soil is unsaturated. Bishop (1959) wrote its effective stress as σ′ = ( σ − ua ) + χ · ( ua − uw ), with χ between zero for dry soil and one for saturated soil. Suction disappears when the soil wets, so strength that depends on it can be lost after heavy rain or a leaking pipe. The capillary contribution is therefore usually ignored in design or used with caution.
Upward Seepage and the Quick Condition
Vertical flow adds a seepage force to the skeleton. Downward flow increases effective stress, which is why dewatering compresses the layers above an aquifer. Upward flow reduces it: at depth z within the flowing layer, σ′ = z · ( γ′ − i · γw ), where i is the hydraulic gradient. Effective stress reaches zero at the critical gradient:
ic = γ′ / γw
where ic is the critical hydraulic gradient (dimensionless), γ′ is the submerged unit weight (kN/m³) and γw is the unit weight of water (kN/m³). In terms of specific gravity Gs and void ratio e it equals ( Gs − 1 ) / ( 1 + e ), which is 1.00 for Gs = 2.65 and e = 0.65.
At that gradient a cohesionless soil has no frictional strength and behaves as a heavy fluid. This is the quick condition; quicksand is a condition of flow, not a type of sand. For the example sand, with γ′ = 10.19 kN/m³, the critical gradient is about 1.04. In the artesian case, the upward gradient through the clay is 3 m of head over 6 m, or 0.5, against a critical value of 9.19 / 9.81 = 0.94.
The usual setting is the base of an excavation below the groundwater table, where the flow path shortens. EN 1997-1 treats the consequences as the UPL (uplift) and HYD (hydraulic heave) limit states.
Horizontal Effective Stress and K₀
In level ground that has not strained laterally, the horizontal stress follows the earth pressure at rest coefficient, and the relationship holds for effective stresses only:
σ′h = K₀ · σ′v
where σ′h is the horizontal effective stress (kPa), K₀ is the coefficient of earth pressure at rest and σ′v is the vertical effective stress (kPa).
For normally consolidated soil Jáky (1944) gives K₀ = 1 − sin φ′, and Mayne and Kulhawy (1982) multiplied this by OCR raised to the power sin φ′ for overconsolidated soil. Pore pressure is isotropic, so the total horizontal stress is σ′h + u.
For the clay at 10 m with φ′ = 25°, K₀ = 0.577, σ′h = 0.577 · 111.52 = 64.35 kPa and the total horizontal stress 64.35 + 78.48 = 142.83 kPa. Applying K₀ to the total vertical stress gives 0.577 · 190 = 109.63 kPa, about 23 per cent too low.
K₀ is not a ratio of total stresses. It belongs to the soil skeleton, and the water has to be added back separately.
Why Does a Change in Groundwater Level Change Every Result?
Because nearly every design method enters through effective stress. If the water table in the example rises from 2 m to the surface, the total stress at 10 m increases from 190 to 194 kPa as the upper sand saturates, the pore pressure from 78.48 to 98.10 kPa, and the effective stress falls from 111.52 to 95.90 kPa, 14 per cent lower. Each metre of rise removes 9.81 − ( 20 − 18 ) = 7.81 kPa below the water table, with no soil parameter changed.
Groundwater does not weaken soil. It removes the stress that soil uses to be strong.
| Result | How effective stress enters | Effect of a rising water table |
|---|---|---|
| Shallow bearing capacity | Effective overburden and γ′ below the footing (Terzaghi, 1943; Meyerhof, 1963) | Falls; γ′ is roughly half the bulk unit weight |
| Consolidation settlement | Initial σ′v0 relative to preconsolidation pressure | A later fall in level adds stress and settlement |
| su from su / σ′v | Normalising stress | Lower estimated su |
| Liquefaction triggering | Cyclic stress ratio scales with σv / σ′v (Seed and Idriss, 1971) | 1.70 to 2.02 at 10 m in the example |
| SPT correction | CN = ( Pa / σ′v )^0.5 (Liao and Whitman, 1986) | CN and N1,60 increase |
| Earth pressure | K · σ′v plus full water pressure | At-rest total stress at 10 m: 142.83 to 153.43 kPa |
| Pile shaft (β method) | fs = β · σ′v (Burland, 1973) | Falls with σ′v |
In liquefaction analysis the demand grows by about 19 per cent, so the design water level dominates the result. Settlement works the other way: long-term pumping drives consolidation settlement in clay that carries no new load.
Why Do Two Engineers Get Different Effective Stress Profiles?
Because the most routine inputs are the ones chosen most differently.
The first is the water level: a reading at the end of drilling may not have stabilised, and a piezometer reflects one season. EN 1997-1 requires design groundwater pressures to represent the most unfavourable values that could occur during the design lifetime. In the example, a water table at 4 m instead of 2 m raises the effective stress at 10 m from 111.52 to 127.14 kPa, about 14 per cent.
The second is the unit weight above the water table. Using the saturated value throughout raises the effective stress at 10 m by 3.6 per cent. Taking γw as 10 kN/m³ rather than 9.81 kN/m³ changes it at 15 m by about 1.5 per cent.
The third, and the largest, is an artesian or perched condition that one engineer recognises and the other does not. Ignoring the artesian head in the example overstates the effective stress at the top of the lower sand by 29.43 kPa, with both profiles arithmetically correct.
When Is the Simple Hydrostatic Assumption Not Appropriate?
Wherever water is moving or pore pressure is out of equilibrium with a single free surface.
Confined aquifers, sites near pumping wells and slopes with seepage toward the face require piezometric data or a seepage analysis rather than an assumed water table. At riverbanks and coastal sites a rapid fall in external level leaves pore pressure in the soil higher than the new level suggests.
Time-dependent loading is the second case. A quickly loaded clay carries the load first as excess pore pressure, and effective stress increases only as it dissipates, following Terzaghi’s one-dimensional consolidation theory. Earthquake shaking generates excess pore pressure in loose saturated sand in the same way. In arid or seasonally dry soils suction controls behaviour, and a single pore pressure does not exist.
Common Errors in Effective Stress Calculations
| Error | Consequence |
|---|---|
| Water level read before it stabilised | Effective stress wrong at every depth below it |
| Saturated unit weight used above the water table | Total and effective stress overstated |
| Artesian head in a confined layer ignored | Effective stress overstated; uplift not checked |
| K₀ applied to total vertical stress | Horizontal stress 23 per cent low in the example |
| Capillary suction relied on for permanent strength | Strength lost when the soil wets |
| Perched level treated as the regional water table | Pore pressure overstated below the lens |
| Design water level not varied for season or flood | Critical case never analysed |
Where SETAF2018 Fits
SETAF2018 treats the effective stress profile as part of the borehole definition rather than as a hand calculation repeated in each analysis.
The groundwater level is entered with the borehole, and each soil layer carries its own properties, including artesian pressure and, for silty layers above the groundwater level, capillarity. Saturated, dry and submerged unit weights can be calculated from the index properties or entered directly, so every input that shapes the profile is stored once and reviewed in one place.
From that soil profile the program draws diagrams of total stress, hydrostatic pore water pressure, vertical effective stress, horizontal effective stress and horizontal total stress, the horizontal values derived from the coefficient of earth pressure at rest. Stresses can also be calculated at any selected depth, with the capillarity and artesian conditions of each layer reflected.
The Mass Stress Analysis tool works on the same profile, adding the stress increase beneath a foundation by the Boussinesq solution for shallow foundations and the Mindlin–Geddes equations for rigid columns and piles. Those increments, with the in-situ effective stress, are the starting point of the settlement calculation.
Because the profile is shared, a change in groundwater level is carried into the analyses that read the same borehole: foundation bearing capacity and settlement, and the liquefaction assessment under TBDY 2018 (Turkish Building Earthquake Code) Annex 16B. Excavation support uses the same layers, with the groundwater level behind the wall defined for each section. The program does not perform seepage or flow-net analysis, so heave under upward flow remains an engineering check from measured piezometric heads.
The stress diagrams sit within the wider set of graphs and analyses, where the effective stress profile behind every result in SETAF2018 can be inspected before a design value is accepted.
Frequently Asked Questions
What is effective stress?
It is the part of the total stress carried through the contacts between soil particles, equal to total stress minus pore water pressure. It governs compression, shear strength and stiffness, so almost every geotechnical calculation requires it first.
What is the difference between total stress and effective stress?
Total stress is the full weight of soil, water and applied load above a point. Effective stress is what remains after subtracting pore water pressure. Only effective stress controls the strength and deformation of the soil skeleton.
How is pore water pressure calculated?
Under hydrostatic conditions it is the unit weight of water multiplied by the depth below the water table, about 9.81 kPa per metre. Where water is confined, perched or flowing, it has to come from piezometer readings or a seepage analysis.
What is artesian pressure?
It is pore pressure above the hydrostatic value in a permeable layer confined beneath a low-permeability layer and recharged from higher ground. It reduces effective stress and can lift the confining layer at the base of an excavation.
Does capillary rise increase effective stress?
Yes, within the saturated capillary fringe, where the pore water is in tension and the pore pressure negative. Because suction is lost when the soil wets, the increase is usually ignored or used cautiously in design.
What is the quick condition?
It is the state in which upward seepage reduces the effective stress in a cohesionless soil to zero. The critical gradient equals the submerged unit weight divided by the unit weight of water, typically close to 1.0.
Why does a rising water table reduce bearing capacity?
Because bearing capacity depends on effective stress. A rising water table reduces the effective overburden at founding level and replaces the bulk unit weight below the footing with the submerged unit weight, roughly half of it, while strength parameters stay unchanged.
Is effective stress the same in all directions?